Description
Return additiveTotal=soluteVolume+carrierVolume and contraction=additiveTotal-measuredTotal, requiring nonnegative volumes.
A ratio compares quantities under a stated numerator and denominator. Fractions, percentage numerals, and percentage-point changes use different conventions, and changing a part can also change its whole. Unit consistency, zero denominators, rounding, and the order of adjustments determine the result.
Return additiveTotal=soluteVolume+carrierVolume and contraction=additiveTotal-measuredTotal, requiring nonnegative volumes.
When to use this tool
Use Dilution Carrier Volume Additivity Gap when you need this specific ratio, allocation, transformation, interval, or adjustment-order calculation with an explicit base.
How to use the tool and how it works
- Enter soluteVolume, carrierVolume, measuredTotal. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read additiveTotal, contraction. Use the output convention below.
Return additiveTotal=soluteVolume+carrierVolume and contraction=additiveTotal-measuredTotal, requiring nonnegative volumes.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| soluteVolume | Solute Volume | Required. Finite number; minimum 0. |
| carrierVolume | Carrier Volume | Required. Finite number; minimum 0. |
| measuredTotal | Measured Total | Required. Finite number; minimum 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| additiveTotal | Additive Total | Required. Finite number. |
| contraction | Contraction | Required. Finite number. |
{
"input": {
"soluteVolume": 20,
"carrierVolume": 80,
"measuredTotal": 98
},
"output": {
"additiveTotal": 100,
"contraction": 2
}
} Limitations and assumptions
- Negative contraction represents a measured total above the additive model. The tool does not infer density, chemistry, temperature, conservation quality, or a safe mixing procedure.
- The field tables state structural bounds; the mechanics also specify cross-field constraints. Malformed inputs and unsupported domains cause errors. A successful false flag, empty branch value, or zero placeholder has the meaning stated above and is distinct from an input error.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.
Alternative or Complementary methods
Check numerator, denominator, units, and adjustment order before comparing results. Use a complete allocation or physical mixture model when a single arithmetic term leaves relevant constraints unspecified.
References
Similar or alternative tools
- Concentration Addition Exact Volume Basis
Use an explicitly measured final volume rather than assuming additive component volumes.
- Ratio Serial Dilution One Logterm
Return logRetention=ln(retainedFraction) and decimalDilution=-log10(retainedFraction), requiring a fraction greater than zero through one.