Skip to content

Main content

Canopy Ndre One Band Pair Term Tool

Calculate canopy ndre one band pair term from explicit caller-supplied inputs.

Loading tool…

Description

Require nearInfrared+redEdge nonzero and return ndre=(nearInfrared-redEdge)/(nearInfrared+redEdge).

Precision-agriculture measurements combine spatial cells, sensor clocks, travel speeds, band signals, and application records. A correction or weighted share is meaningful only when coordinate frames, units, timestamps, and coverage bases agree. Supplied calibration and support flags remain distinct from measurements that establish them.

Require nearInfrared+redEdge nonzero and return ndre=(nearInfrared-redEdge)/(nearInfrared+redEdge).

When to use this tool

Use Canopy Ndre One Band Pair Term when you have the stated field, sensor, map, or application records and need this correction or geometric/accounting component.

How to use the tool and how it works

  1. Enter nearInfrared, redEdge. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read ndre. Use the output convention below.

Require nearInfrared+redEdge nonzero and return ndre=(nearInfrared-redEdge)/(nearInfrared+redEdge).1

Input fieldMeaning and unitsAccepted input
nearInfraredNear InfraredRequired. Finite number.
redEdgeRed EdgeRequired. Finite number.
Output fieldInterpretationReturned shape
ndreNdreRequired. Finite number.
json
{
  "input": {
    "nearInfrared": 0.6,
    "redEdge": 0.2
  },
  "output": {
    "ndre": 0.49999999999999994
  }
}

Limitations and assumptions

  • Band values must use a compatible reflectance scale. Signed bands are accepted and the result is not clamped; the calculation does not perform imagery calibration or crop diagnosis.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.

Alternative or Complementary methods

Verify the measurement calibration, coordinate frame, spatial support, and clock convention before combining this term into a map or control workflow. Use a complete equipment or field model when geometric and operating constraints matter.

References

  1. Calculation and input contract: precision-agriculture/canopy-ndre-one-band-pair-term — tool.io

Similar or alternative tools