Description
Locate samples meeting an explicit sensor saturation rule without estimating true pressure above saturation.
Foot and footwear research uses geometric dimensions, contact cells, forces, and measurement records. A length margin, normalized difference, or contact share has a specific measurement basis and can omit important three-dimensional or sensor effects. Arithmetic on supplied observations is separate from a validated clinical assessment.
Locate samples meeting an explicit sensor saturation rule without estimating true pressure above saturation.
When to use this tool
Use Plantar Pressure Saturated Sample Token when you have supplied foot, footwear, bench, or recording data and need this measurement or record-support calculation.
How to use the tool and how it works
- Enter samples, saturationLevel, equalitySaturated. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read saturatedPositions, saturatedCount. Use the output convention below.
Return zero-based saturatedPositions and saturatedCount where samples>=saturationLevel if equalitySaturated, otherwise samples>saturationLevel.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| samples | Samples | Required. Array of finite number; maximum items 256. |
| saturationLevel | Saturation Level | Required. Finite number. |
| equalitySaturated | Equality Saturated | Required. Boolean. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| saturatedPositions | Saturated Positions | Required. Array of safe integer; maximum items 256. |
| saturatedCount | Saturated Count | Required. Safe integer. |
{
"input": {
"samples": [
5,
10,
12
],
"saturationLevel": 10,
"equalitySaturated": true
},
"output": {
"saturatedPositions": [
1,
2
],
"saturatedCount": 2
}
} Limitations and assumptions
- Threshold and samples need a common measurement scale. The threshold is supplied and saturation flags do not validate sensor calibration or reveal the true clipped pressure.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.
Alternative or Complementary methods
Use a documented measurement protocol with calibrated equipment and appropriate geometric or contact models. Broader interpretation requires assessment of the underlying observations beyond one length, ratio, or support flag.
References
Similar or alternative tools
- Plantar Pressure Cell Force
Convert one supplied sensor-cell pressure and area to force using explicit compatible SI unit factors; no gait interpretation.
- Foot Pressure Cell Area Factor
Return one supplied bench pressure-area force contribution in compatible units.