Plumbing Radiant Manifold Flow Calculator
Audit actual radiant manifold port evidence and independent header meter, preserving missing ports/signed closure discrepancy; not summing assumed zone demands or distributing flow equally.
Description
A manifold closure audit distinguishes known port flows from missing evidence.
A manifold closure audit distinguishes known port flows from missing evidence. Header-minus-known flow remains signed.1
The returned values include Known port flow liters minute, Unknown port count, Signed header minus known ports liters minute, Fully observed manifold closure. The How section below explains the calculation, input rules and interpretation.
When to use Plumbing Radiant Manifold Flow Calculator
Use Plumbing Radiant Manifold Flow Calculator when you need to evaluate the supplied records under the calculation and evidence rules below. No equal allocation, missing-flow extrapolation or assumed zone demands are supplied.
Prepare measured flows, pressures, temperatures or inventories with consistent units. For catalog tools, use independently verified capacities at the stated operating conditions and supply the explicit design demand.
How to use Plumbing Radiant Manifold Flow Calculator and understand its results
- Prepare measured flows, pressures, temperatures or inventories with consistent units. For catalog tools, use independently verified capacities at the stated operating conditions and supply the explicit design demand.
- Enter observedManifoldPortLitersMinute, manifoldPortEvidenceFlags, observedIndependentHeaderLitersMinute using the field table and calculation rules, then run the tool.
- Read knownPortFlowLitersMinute, unknownPortCount, signedHeaderMinusKnownPortsLitersMinute, fullyObservedManifoldClosure. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| observedManifoldPortLitersMinute | Observed manifold port liters minute | list of number | Required |
| manifoldPortEvidenceFlags | Manifold port evidence flags | list of number | Required |
| observedIndependentHeaderLitersMinute | Observed independent header liters minute | number | Required |
Enter aligned nonempty nonnegative port flows and binary evidence flags, plus nonnegative independent header flow. Return known flow, missing-port count, signed discrepancy and a flag true exactly when every port is observed. The flag does not test numerical agreement.
known=sum(portFlow where evidence=1); discrepancy=header−known Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| knownPortFlowLitersMinute | Known port flow liters minute | number |
| unknownPortCount | Unknown port count | number |
| signedHeaderMinusKnownPortsLitersMinute | Signed header minus known ports liters minute | number |
| fullyObservedManifoldClosure | Fully observed manifold closure | boolean |
{
"input": {
"observedManifoldPortLitersMinute": [
1,
2,
3
],
"manifoldPortEvidenceFlags": [
1,
0,
1
],
"observedIndependentHeaderLitersMinute": 5
},
"output": {
"knownPortFlowLitersMinute": 4,
"unknownPortCount": 1,
"signedHeaderMinusKnownPortsLitersMinute": 1,
"fullyObservedManifoldClosure": false
}
} Limitations and assumptions
No equal allocation, missing-flow extrapolation or assumed zone demands are supplied.
Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Numeric lists are limited to 10,000 entries; string lists to 128 strings of at most 128 characters each. The rules above may impose smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.
Alternative or Complementary methods
Use Plumbing Hydronic Heating Flow Rate Calculator: Hydronic heat delivery depends on volumetric heat capacity and supply-return temperature difference. Parallel zone flow demands add. For a complementary task, use Plumbing Radiant Floor Heat Output Calculator: A linear floor-emission model uses surface-to-room temperature difference, area and an effective emission coefficient. Cooling remains negative.
References
Similar or alternative tools
- Plumbing Hydronic Heating Flow Rate Calculator
Hydronic heat delivery depends on volumetric heat capacity and supply-return temperature difference. Parallel zone flow demands add.
- Plumbing Radiant Floor Heat Output Calculator
A linear floor-emission model uses surface-to-room temperature difference, area and an effective emission coefficient. Cooling remains negative.