Plumbing Greywater System Size Calculator

Reconcile actual independent recoverable greywater and compatible reuse daily budgets under caller recovery, no carryover; no wastewater quality, cross-connection or safe reuse approval.

Description

Greywater reuse budgets compare recovered daily volume with compatible demand.

Greywater reuse budgets compare recovered daily volume with compatible demand. Without carryover, unused supply and unmet demand are separate.1

The returned values include Modeled recoverable greywater liters day, Modeled unmet reuse demand liters day, Modeled unused greywater liters day. The How section below explains the calculation, input rules and interpretation.

When to use Plumbing Greywater System Size Calculator

Use Plumbing Greywater System Size Calculator when you need to evaluate the supplied records under the calculation and evidence rules below. No storage carryover, water quality, cross-connection or safe-reuse approval is supplied.

Prepare measured flows, pressures, temperatures or inventories with consistent units. For catalog tools, use independently verified capacities at the stated operating conditions and supply the explicit design demand.

How to use Plumbing Greywater System Size Calculator and understand its results

  1. Prepare measured flows, pressures, temperatures or inventories with consistent units. For catalog tools, use independently verified capacities at the stated operating conditions and supply the explicit design demand.
  2. Enter observedRecoverableGreywaterLitersDay, callerCompatibleReuseDemandLitersDay, callerTreatmentRecoveryFraction using the field table and calculation rules, then run the tool.
  3. Read modeledRecoverableGreywaterLitersDay, modeledUnmetReuseDemandLitersDay, modeledUnusedGreywaterLitersDay. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
observedRecoverableGreywaterLitersDayObserved recoverable greywater liters daylist of numberRequired
callerCompatibleReuseDemandLitersDayCaller compatible reuse demand liters daylist of numberRequired
callerTreatmentRecoveryFractionCaller treatment recovery fractionnumberRequired

Enter aligned nonempty nonnegative recoverable and reuse-demand liters/day plus recovery fraction 0–1. Return recovered, unmet and unused daily volumes.

recovered_i=raw_i×recovery; unmet_i=max(0,demand_i−recovered_i); unused_i=max(0,recovered_i−demand_i)

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
modeledRecoverableGreywaterLitersDayModeled recoverable greywater liters daylist of number
modeledUnmetReuseDemandLitersDayModeled unmet reuse demand liters daylist of number
modeledUnusedGreywaterLitersDayModeled unused greywater liters daylist of number
json
{
  "input": {
    "observedRecoverableGreywaterLitersDay": [
      100,
      150
    ],
    "callerCompatibleReuseDemandLitersDay": [
      80,
      200
    ],
    "callerTreatmentRecoveryFraction": 0.8
  },
  "output": {
    "modeledRecoverableGreywaterLitersDay": [
      80,
      120
    ],
    "modeledUnmetReuseDemandLitersDay": [
      0,
      80
    ],
    "modeledUnusedGreywaterLitersDay": [
      0,
      0
    ]
  }
}

Limitations and assumptions

No storage carryover, water quality, cross-connection or safe-reuse approval is supplied.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Numeric lists are limited to 10,000 entries; string lists to 128 strings of at most 128 characters each. The rules above may impose smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use Plumbing Rainwater Harvesting Tank Size Calculator: Rainwater inventory depends on the chronological collection and withdrawal ledger. Starting empty exposes withdrawals that cannot be served. For a complementary task, use Plumbing Septic Tank Size Calculator: Septic storage combines liquid retention with separate sludge and emergency reserves. Measured mean daily wastewater sets the liquid budget.

References

  1. Plumbing Greywater System Size Calculator — tool.io

Similar or alternative tools

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies