Plumbing Aggressive Index Calculator

Declared AWWAC400aggressive index AI=pH+log10(AH), Aalkalinity/Hcalciumhardnessmg/L asCaCO3. Not Langelier SAT index, conductivity or corrodes-any-material verdict. Actual independently matched units, regime, material/equipment and governing references; not a hydraulic code, safe pressure, water pot ability or operational approval.

Description

An aggressive index combines measured pH, alkalinity and calcium hardness under a stated convention.

An aggressive index combines measured pH, alkalinity and calcium hardness under a stated convention.1

It differs from a saturation index and does not establish corrosion for every material. The calculation and input requirements are explained below.

When to use Plumbing Aggressive Index Calculator

Enter finite measured pH and positive alkalinity and calcium hardness in mg/L as CaCO3.

How to use Plumbing Aggressive Index Calculator and how it works

  1. Prepare the measurements or independently established model inputs described below, with matching units and observation scope.
  2. Enter the required fields and run Plumbing Aggressive Index Calculator.
  3. Read the result fields using the formula, output units, signs and ordering explained below.
  4. Correct any rejected inputs and rerun; interpret the result within the stated model and its assumptions.
Input fieldMeaningValue typeRequirement
actualMeasuredPhActual Measured Ph. Use the units and matching context stated in the calculation below.numberRequired; finite; other constraints below
actualAlkalinityMgPerLiterAsCaco3Actual Alkalinity Mg Per Liter As Caco3. Use the units and matching context stated in the calculation below.numberRequired; strictly positive; finite; other constraints below
actualCalciumHardnessMgPerLiterAsCaco3Actual Calcium Hardness Mg Per Liter As Caco3. Use the units and matching context stated in the calculation below.numberRequired; strictly positive; finite; other constraints below

Enter finite measured pH and positive alkalinity and calcium hardness in mg/L as CaCO3. Return pH+log10(alkalinity*hardness). No universal aggression band or material-corrosion verdict is assigned.

aggressiveIndex=pH+log10(alkalinity*calciumHardness)

Apply the input ordering, units and branch conditions stated above.

Output fieldMeaningValue type
resultObject containing the calculated or selected fields below.object
result.valueNumeric result under the formula and output units explained above.number
json
{
  "input": {
    "actualMeasuredPh": 8,
    "actualAlkalinityMgPerLiterAsCaco3": 10,
    "actualCalciumHardnessMgPerLiterAsCaco3": 10
  },
  "output": {
    "result": {
      "value": 10
    }
  }
}

Limitations and assumptions

The calculation uses the supplied observations and model inputs. It does not collect measurements, select a reference population or coefficient, or establish that the model applies to the actual case. The stated branch conditions and output units remain part of the result.

All fields require explicit values. Unexpected fields, wrong types, nonfinite numbers and sparse arrays are rejected. Alignment, bounds and supported-token rules are explained above; extremely large inputs or nonfinite results can also fail. Input errors differ from successful false comparisons, unavailable-domain flags and empty match lists.

Alternative or Complementary methods

Use Plumbing Water Softener Regeneration Frequency Calculator for a complementary operation: A softener's exhaustion interval compares usable exchange capacity with daily hardness load.

Use Plumbing Water Hardness Grains Per Gallon Calculator for a complementary operation: Water hardness is often expressed as calcium-carbonate-equivalent mass per volume.

References

  1. Plumbing Aggressive Index Calculator — tool.io