Description
One linear or logarithmic research AUC panel under an explicit convention.
Pharmacokinetic research describes concentration over time using measurement units and an explicit model. Concentration-time area, its time-weighted moment, inverse-time rate constants, clearance, and volume are related but distinct quantities. A conversion or local model term does not estimate every parameter or validate a complete study.
One linear or logarithmic research AUC panel under an explicit convention.
When to use this tool
Use PK AUC One Trapezoid Panel when you need this concentration-time conversion, sampling check, local integral panel, or explicitly supplied kinetic-model term.
How to use the tool and how it works
- Enter firstTime, secondTime, firstConcentration, secondConcentration, logarithmic. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read area, duration. Use the output convention below.
Require secondTime>=firstTime and nonnegative concentrations, both positive if logarithmic. If logarithmic and concentrations differ, return area=duration*(secondConcentration-firstConcentration)/(ln(secondConcentration)-ln(firstConcentration)); otherwise use duration*(firstConcentration+secondConcentration)/2. Also return duration.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| firstTime | First Time | Required. Finite number. |
| secondTime | Second Time | Required. Finite number. |
| firstConcentration | First Concentration | Required. Finite number. |
| secondConcentration | Second Concentration | Required. Finite number. |
| logarithmic | Logarithmic | Required. Boolean. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| area | Area in a unit compatible with the other physical inputs. | Required. Finite number. |
| duration | Duration | Required. Finite number. |
{
"input": {
"firstTime": 0,
"secondTime": 2,
"firstConcentration": 8,
"secondConcentration": 4,
"logarithmic": false
},
"output": {
"area": 12,
"duration": 2
}
} Limitations and assumptions
- The chosen panel rule is explicit and not an automatic linear-up/log-down policy. Time and concentration units determine the AUC unit; one panel does not estimate total exposure or an extrapolated terminal tail.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.
Alternative or Complementary methods
Use a complete study analysis when a local panel, transformation, or model factor is insufficient. Check sampling times, censoring, assay support, unit conventions, and the validity of the assumed kinetic regime.
References
Similar or alternative tools
- PK AUMC One Trapezoid Panel
Return momentArea=(secondTime-firstTime)*(firstTime*firstConcentration+secondTime*secondConcentration)/2 and concentrationArea=(secondTime-firstTime)*(firstConcentration+secondConcentration)/2.
- PK Clearance Research AUC Unit Factor
Research amount/AUC arithmetic with supplied unit bases and bioavailability.