Description
Compare explicit nonclinical sample clocks; no dose, clearance or exposure model.
Pharmacokinetic research describes concentration over time using measurement units and an explicit model. Concentration-time area, its time-weighted moment, inverse-time rate constants, clearance, and volume are related but distinct quantities. A conversion or local model term does not estimate every parameter or validate a complete study.
Compare explicit nonclinical sample clocks; no dose, clearance or exposure model.
When to use this tool
Use Nonclinical Sample Time Gap when you need this concentration-time conversion, sampling check, local integral panel, or explicitly supplied kinetic-model term.
How to use the tool and how it works
- Enter plannedTimes, measuredTimes, suppliedOrigin. Keep parallel arrays aligned. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read plannedRelative, measuredRelative, timingResiduals. Use the output convention below.
Require equally sized plannedTimes and measuredTimes. Subtract suppliedOrigin from each array into plannedRelative and measuredRelative, and return timingResiduals=measured-planned.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| plannedTimes | Planned Times | Required. Array of finite number; maximum items 256. |
| measuredTimes | Measured Times | Required. Array of finite number; maximum items 256. |
| suppliedOrigin | Supplied Origin | Required. Finite number. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| plannedRelative | Planned Relative | Required. Array of finite number; maximum items 256. |
| measuredRelative | Measured Relative | Required. Array of finite number; maximum items 256. |
| timingResiduals | Timing Residuals | Required. Array of finite number; maximum items 256. |
{
"input": {
"plannedTimes": [
10,
20
],
"measuredTimes": [
11,
19
],
"suppliedOrigin": 5
},
"output": {
"plannedRelative": [
5,
15
],
"measuredRelative": [
6,
14
],
"timingResiduals": [
1,
-1
]
}
} Limitations and assumptions
- All times need one unit and origin. Empty lists and unordered times are accepted; this does not match samples, estimate clock drift, or validate a sampling protocol.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.
Alternative or Complementary methods
Use a complete study analysis when a local panel, transformation, or model factor is insufficient. Check sampling times, censoring, assay support, unit conventions, and the validity of the assumed kinetic regime.
References
Similar or alternative tools
- Concentration Time Unit Factor
Convert an already supplied nonclinical concentration-time quantity using explicit compatible unit factors.
- Nonclinical Concentration Logstep
Compare explicitly supplied nonclinical concentration observations without dosing or extrapolated patient predictions.