Practical Salinity PSS78 From CTD Converter
UNESCO PSS78 conductivityR=C(S, t, p)/C(35,15,0), pressure correction,2≤S≤42,−2≤IPTS68t≤35, no low-salinity or conductivity-units ambiguity. Caller independently establishes units, regime, calibration and applicability; this does not establish design-code compliance, authenticity, operational safety, treatment efficacy or a validated forecast.
Description
Practical Salinity on PSS-78 is calculated from a conductivity ratio corrected for temperature and pressure.
When to use Practical Salinity PSS78 From CTD Converter
Use this tool to calculate or review the supplied observations under the stated rules. Match the observation interval, units, datum, coordinate signs and model regime.
How to use Practical Salinity PSS78 From CTD Converter and understand its results
- Match the observation interval, units, datum, coordinate signs and model regime.
- Enter observedConductivityRatioToC35150, temperatureIpts68C, pressureDbar, using the field meanings and rules below, then run the tool.
- Read practicalSalinityPss78. Inspect nested result fields where present, and review unknown records separately from known matches.
- Correct any reported input issue and run again. Before using a successful result, check the stated units, signs, reference scope and observation coverage.
| Input field | Meaning | Value type | Requirement |
|---|---|---|---|
| observedConductivityRatioToC35150 | Observed conductivity ratio to c35150 | number | Required |
| temperatureIpts68C | Temperature ipts68 c | number | Required |
| pressureDbar | Pressure dbar | number | Required |
Require positive R=C(S,t,p)/C(35,15,0), IPTS-68 temperature −2..35 °C and gauge pressure 0..10000 dbar. Calculate the temperature reference polynomial rt and pressure factor rp; require R/(rt×rp)>0. Evaluate the two six-coefficient PSS-78 polynomials in sqrt(R/(rt×rp)), combining them with (t−15)/(1+.0162(t−15)). Reject resulting salinity outside 2..42. No low-salinity extension is implemented.
S=A(x)+[(t−15)/(1+.0162(t−15))]B(x); x=√[R/(rt rp)] Use the matching field units and the exact boundary, ordering and reference rules above.
| Output field | Meaning | Value type |
|---|---|---|
| practicalSalinityPss78 | Practical salinity pss78 | number |
{
"input": {
"observedConductivityRatioToC35150": 1,
"temperatureIpts68C": 15,
"pressureDbar": 0
},
"output": {
"practicalSalinityPss78": 34.99999992412809
}
} Limitations and assumptions
The stated observation or model covers only the supplied record and reference regime. It does not fill missing measurements, supply uncertainty estimates or produce a validated forecast.
Missing required fields, unknown fields, wrong types and violated rules return input issues. Numeric values and outputs must be finite.
Alternative or Complementary methods
For a related step, use Potential Temperature UNESCO Adiabatic Calculator: Potential temperature is the temperature a water parcel would have after an adiabatic move to a reference pressure. For a complementary comparison, use Potential Density Sigma Theta Calculator: Potential density evaluates a parcel at its potential temperature and a chosen reference pressure.
References
Similar or alternative tools
- Potential Temperature UNESCO Adiabatic Calculator
Potential temperature is the temperature a water parcel would have after an adiabatic move to a reference pressure.
- Potential Density Sigma Theta Calculator
Potential density evaluates a parcel at its potential temperature and a chosen reference pressure.