H-Reflex Latency Calculator
Actual sampled peak latency for independently identified H-reflex response, not response onset. Supplied component-specific window, baseline, stimulus zero, artifact rejection and polarity independently established; ties retained, no norm/diagnosis or sub-sample interpolation.
Description
An H-reflex has an identified component peak and a separately determined onset.
An H-reflex has an identified component peak and a separately determined onset.1
This tool extracts a positive peak within a supplied window rather than an onset detector.
When to use H-Reflex Latency Calculator
Use this tool to calculate or review the supplied observations under the stated rules. Establish the assessment or recording protocol, units, instrument version and independently applicable reference or calibration.
How to use H-Reflex Latency Calculator and understand its results
- Establish the assessment or recording protocol, units, instrument version and independently applicable reference or calibration.
- Enter independentlyMeasuredStimulusRelativeTimesMs, independentlyMeasuredBaselineCorrectedAmplitudes, callerIdentifiedComponentWindowStartMs, callerIdentifiedComponentWindowEndMs, using the field meanings and rules below, then run the tool.
- Read result.sampledPeakTime, result.sampledPeakAmplitude, result.tiedSampledPeakTimes. Use the units and sign conventions below.
- Correct any reported input issue and run again. Before using a successful result, check the stated units, signs, reference scope and observation coverage.
| Input field | Meaning | Value type | Requirement |
|---|---|---|---|
| independentlyMeasuredStimulusRelativeTimesMs | Independently measured stimulus relative times ms | list of number | Required |
| independentlyMeasuredBaselineCorrectedAmplitudes | Independently measured baseline corrected amplitudes | list of number | Required |
| callerIdentifiedComponentWindowStartMs | Caller identified component window start ms | number | Required |
| callerIdentifiedComponentWindowEndMs | Caller identified component window end ms | number | Required |
Enter at least two aligned finite time and baseline-corrected amplitude samples with strictly increasing times. Supply an ordered component window; at least one sample must lie inside its inclusive boundaries. Select the largest positive excursion inside that window; the winning polarity-adjusted amplitude must be strictly positive. Return the first tied peak time, its original signed amplitude and all exactly tied peak times. Time coordinates may be signed and no interpolation, filtering, baseline estimation, component recognition or onset detection is added.
indices={i:windowStart≤time_i≤windowEnd}; peak=max(1×amplitude_i), peak>0; selectedTime=first time attaining peak Use the matching field units and the exact boundary, ordering and reference rules above.
| Output field | Meaning | Value type |
|---|---|---|
| result | Structured result; its nested fields below contain the actual calculation or selected reference | object |
| result.sampledPeakTime | Time in milliseconds of the first sample attaining the selected-polarity maximum inside the inclusive window | number |
| result.sampledPeakAmplitude | Original signed amplitude at that first selected peak; in the supplied recording amplitude unit | number |
| result.tiedSampledPeakTimes | All exactly tied selected peak times in milliseconds, preserving sample order | list |
{
"input": {
"independentlyMeasuredStimulusRelativeTimesMs": [
1,
2,
3,
4
],
"independentlyMeasuredBaselineCorrectedAmplitudes": [
0,
2,
2,
0
],
"callerIdentifiedComponentWindowStartMs": 1,
"callerIdentifiedComponentWindowEndMs": 4
},
"output": {
"result": {
"sampledPeakTime": 2,
"sampledPeakAmplitude": 2,
"tiedSampledPeakTimes": [
2,
3
]
}
}
} Limitations and assumptions
Actual acquisition, assessment protocol, instrument version and calibration determine applicability. The tool does not examine a person, classify images, administer a questionnaire or choose diagnostic cutoffs.
Missing required fields, unknown fields, wrong types and violated rules return input issues. Numeric values and outputs must be finite. Lists and matrices must be dense, without missing cells. Numeric lists allow at most 10000 entries; ordinary string lists allow at most 128 strings of 128 UTF-16 units each; numeric matrices allow at most 128 rows and 128 columns, subject to narrower requirements above. Extremely large composite outputs are rejected.
Alternative or Complementary methods
For a related step, use MEP Latency Calculator: A motor-evoked response has a component peak and an independently identifiable onset. For a complementary comparison, use F-Wave Latency Calculator: An F-wave recording contains an independently identified late-response component.
References
-
H-Reflex Latency Calculator — tool.io
Similar or alternative tools
- MEP Latency Calculator
A motor-evoked response has a component peak and an independently identifiable onset.
- F-Wave Latency Calculator
An F-wave recording contains an independently identified late-response component.