ABR Interpeak Latency Calculator
Actual independently identified chronological ABRwaveI/III/Vcomponent interpeak latencies. Component identification and same stimulus/acquisition essential; not automatically find peaks or diagnose conduction pathology.
Description
ABR interpeak latencies compare independently identified waves I, III and V.
ABR interpeak latencies compare independently identified waves I, III and V.1
Chronological peak coordinates must refer to the same qualified recording.
When to use ABR Interpeak Latency Calculator
Use this tool to calculate or review the supplied observations under the stated rules. Establish the assessment or recording protocol, units, instrument version and independently applicable reference or calibration.
How to use ABR Interpeak Latency Calculator and understand its results
- Establish the assessment or recording protocol, units, instrument version and independently applicable reference or calibration.
- Enter independentlyIdentifiedWaveOneMs, independentlyIdentifiedWaveThreeMs, independentlyIdentifiedWaveFiveMs, using the field meanings and rules below, then run the tool.
- Read result.observedOneToThreeMs, result.observedThreeToFiveMs, result.observedOneToFiveMs. Use the units and sign conventions below.
- Correct any reported input issue and run again. Before using a successful result, check the stated units, signs, reference scope and observation coverage.
| Input field | Meaning | Value type | Requirement |
|---|---|---|---|
| independentlyIdentifiedWaveOneMs | Independently identified wave one ms | number | Required |
| independentlyIdentifiedWaveThreeMs | Independently identified wave three ms | number | Required |
| independentlyIdentifiedWaveFiveMs | Independently identified wave five ms | number | Required |
Require wave I≥0, wave III≥wave I and wave V≥wave III in milliseconds. Equal peak times are allowed. Return III−I, V−III and V−I without recognizing the waveform or choosing normative limits.
I_III=III−I; III_V=V−III; I_V=V−I Use the matching field units and the exact boundary, ordering and reference rules above.
| Output field | Meaning | Value type |
|---|---|---|
| result | Structured result; its nested fields below contain the actual calculation or selected reference | object |
| result.observedOneToThreeMs | Observed One To Three Ms | number |
| result.observedThreeToFiveMs | Observed Three To Five Ms | number |
| result.observedOneToFiveMs | Observed One To Five Ms | number |
{
"input": {
"independentlyIdentifiedWaveOneMs": 1,
"independentlyIdentifiedWaveThreeMs": 3,
"independentlyIdentifiedWaveFiveMs": 5
},
"output": {
"result": {
"observedOneToThreeMs": 2,
"observedThreeToFiveMs": 2,
"observedOneToFiveMs": 4
}
}
} Limitations and assumptions
Actual acquisition, assessment protocol, instrument version and calibration determine applicability. The tool does not examine a person, classify images, administer a questionnaire or choose diagnostic cutoffs.
Missing required fields, unknown fields, wrong types and violated rules return input issues. Numeric values and outputs must be finite. Extremely large composite outputs are rejected.
Alternative or Complementary methods
For a related step, use VEP P100 Calculator: P100 is an identified component of a visual evoked-potential recording. For a complementary comparison, use SSEP N20 Calculator: N20 is an identified negative component of a somatosensory evoked potential.
References
-
ABR Interpeak Latency Calculator — tool.io
Similar or alternative tools
- VEP P100 Calculator
P100 is an identified component of a visual evoked-potential recording.
- SSEP N20 Calculator
N20 is an identified negative component of a somatosensory evoked potential.