Description
For exact, return value ± quantum / 2 with both bounds marked present.
A reported threshold is not an exact measured value. Censored observations have one available bound, while a rounded exact value can be represented by a finite interval.
For exact, return value ± quantum / 2 with both bounds marked present.
When to use this tool
Use Renal Assay Censored Precision when you need to preserve bound availability rather than treating every number as exact.
How to use the tool and how it works
- Enter value, qualifier, quantum. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read lower, upper, lowerBounded, upperBounded. Inspect lowerBounded, upperBounded before interpreting the associated values.
For exact, return value ± quantum / 2 with both bounds marked present. For less-than, mark only upper = value present; for greater-than, mark only lower = value present.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| value | Value | Required. Finite number. |
| qualifier | Qualifier | Required. Text; one of "exact", "less-than", "greater-than"; maximum UTF-16 length 8192. |
| quantum | Positive rounding increment in the same unit as value. | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| lower | Lower value, meaningful only when lowerBounded is true. | Required. Finite number. |
| upper | Upper value, meaningful only when upperBounded is true. | Required. Finite number. |
| lowerBounded | Lower Bounded | Required. Boolean. |
| upperBounded | Upper Bounded | Required. Boolean. |
{
"input": {
"value": 4,
"qualifier": "less-than",
"quantum": 0.2
},
"output": {
"lower": 0,
"upper": 4,
"lowerBounded": false,
"upperBounded": true
}
} Limitations and assumptions
- An absent bound is stored as zero and must be interpreted through its Boolean flag; no probability distribution or censoring model is fitted.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Retain the original assay qualifier and use an appropriate censored-data method for statistical analysis.
References
Similar or alternative tools
- Renal Assay Activity Molar Unit Flag
When molarBasisKnown is true, divide activity by that factor; otherwise return molarAmount zero and molarDefined false.
- Microbial Blank Negative Case Token
Subtract blank from signal and return separate negative and exact-zero flags.