Fugitometer Equivalent Fading Years Estimator
Express measured fugitometer fading as a caller calibrated reference-equivalent exposure duration; same fade coordinate and linear local response assumed, no lifespan/reversibility guarantee.
Description
A fugitometer measures a chosen fading-coordinate change under exposure.
A fugitometer measures a chosen fading-coordinate change under exposure. Reference-equivalent duration uses a calibrated local response.
Express measured fugitometer fading as a caller calibrated reference-equivalent exposure duration; same fade coordinate and linear local response assumed, no lifespan/reversibility guarantee.
When to use Fugitometer Equivalent Fading Years Estimator
Use this tool to express measured fugitometer fading as a caller calibrated reference-equivalent exposure duration; same fade coordinate and linear local response assumed, no lifespan/reversibility guarantee.
Prepare the collection, exposure, scheduling or financial records required for this calculation. Keep row order and the declared units consistent.
How to use Fugitometer Equivalent Fading Years Estimator and understand its results
- Prepare the collection, exposure, scheduling or financial records required for this calculation. Keep row order and the declared units consistent.
- Enter observedFadeCoordinateChange, testLuxHours, referenceAnnualLuxHours, callerReferenceFadePerLuxHour using the field table and calculation rules, then run the tool.
- Read observedFadePerLuxHour, equivalentReferenceFadingYears. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| observedFadeCoordinateChange | Observed fade coordinate change | number | Required |
| testLuxHours | Test lux hours | number | Required |
| referenceAnnualLuxHours | Reference annual lux hours | number | Required |
| callerReferenceFadePerLuxHour | Caller reference fade per lux hour | number | Required |
Use nonnegative change and positive test dose, annual reference dose and reference response. Return observed change per test dose and reference-equivalent years.1
equivalent years = observed change/(reference fade per lux-hour × annual reference dose) Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| observedFadePerLuxHour | Observed fade per lux hour | number |
| equivalentReferenceFadingYears | Equivalent reference fading years | number |
{
"input": {
"observedFadeCoordinateChange": 2,
"testLuxHours": 100,
"referenceAnnualLuxHours": 1000,
"callerReferenceFadePerLuxHour": 0.01
},
"output": {
"observedFadePerLuxHour": 0.02,
"equivalentReferenceFadingYears": 0.2
}
} Limitations and assumptions
The fade coordinate must match calibration; no lifespan, linearity outside the local regime or reversibility guarantee.
Numbers and computed results must be finite; overflow produces an error. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.
Alternative or Complementary methods
Use Reciprocity Law Failure Adjustment Factor Calculator: Apply caller experimentally calibrated intensity exponent relative to reference illuminance, exposing nonlinear versus linear exposure; no universal reciprocity-failure exponent or damage prediction. For a complementary task, use Light-Sensitive Object Annual Lux-Hours Budget Calculator: Account measured object light exposure and prior annual ledger against caller budget, retaining signed overspend; dose is not a material-safe limit.
References
Similar or alternative tools
- Reciprocity Law Failure Adjustment Factor Calculator
Apply caller experimentally calibrated intensity exponent relative to reference illuminance, exposing nonlinear versus linear exposure; no universal reciprocity-failure exponent or damage prediction.
- Light-Sensitive Object Annual Lux-Hours Budget Calculator
Account measured object light exposure and prior annual ledger against caller budget, retaining signed overspend; dose is not a material-safe limit.