Environmental Excursion Alert Threshold Breach Counter

Retain environmental excursion sample count, contiguous episode count, actual exposure and magnitude×duration as different summaries; measurements represent declared intervals, not intersample interpolation or damage.

Description

Excursion samples, episodes, hours and severity describe different properties.

Excursion samples, episodes, hours and severity describe different properties. A contiguous breach can contain multiple samples.

Retain environmental excursion sample count, contiguous episode count, actual exposure and magnitude×duration as different summaries; measurements represent declared intervals, not intersample interpolation or damage.

When to use Environmental Excursion Alert Threshold Breach Counter

Use this tool to retain environmental excursion sample count, contiguous episode count, actual exposure and magnitude×duration as different summaries; measurements represent declared intervals, not intersample interpolation or damage.

Prepare the collection, exposure, scheduling or financial records required for this calculation. Keep row order and the declared units consistent.

How to use Environmental Excursion Alert Threshold Breach Counter and understand its results

  1. Prepare the collection, exposure, scheduling or financial records required for this calculation. Keep row order and the declared units consistent.
  2. Enter observedValues, representedExposureHours, callerAllowedLowerValue, callerAllowedUpperValue using the field table and calculation rules, then run the tool.
  3. Read breachSampleCount, breachEpisodeCount, breachExposureHours, breachSeverityValueHours. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
observedValuesObserved valueslist of numberRequired
representedExposureHoursRepresented exposure hourslist of numberRequired
callerAllowedLowerValueCaller allowed lower valuenumberRequired
callerAllowedUpperValueCaller allowed upper valuenumberRequired

Align observations and nonnegative exposure hours with ordered lower/upper bounds. Endpoints are inside the band. Count strict breaches and consecutive episodes, and sum exposure and magnitude-hours without interpolation.1

Paired lists must be nonempty and have equal lengths.

severity = Σ distance outside allowed band × represented hours

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
breachSampleCountBreach sample countnumber
breachEpisodeCountBreach episode countnumber
breachExposureHoursBreach exposure hoursnumber
breachSeverityValueHoursBreach severity value hoursnumber
json
{
  "input": {
    "observedValues": [
      5,
      12,
      13,
      5
    ],
    "representedExposureHours": [
      1,
      2,
      1,
      3
    ],
    "callerAllowedLowerValue": 0,
    "callerAllowedUpperValue": 10
  },
  "output": {
    "breachSampleCount": 2,
    "breachEpisodeCount": 1,
    "breachExposureHours": 3,
    "breachSeverityValueHours": 7
  }
}

Limitations and assumptions

Declared intervals are assumed representative; these metrics do not measure damage.

Numbers and computed results must be finite; overflow produces an error. Numeric lists are limited to 100,000 entries; the rules above may require smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use Temperature Daily Swing Tolerance Checker: Integrate exact piecewise-linear daily temperature degree-hours outside caller center/band and retain measured swing; unlike RH range/slew, this is excursion magnitude×duration, not preservation safety. For a complementary task, use RH Daily Fluctuation Tolerance Band Checker: Audit observed full-day RH range and resolved maximum slew as distinct caller fluctuation criteria; unresolved intersample extremes remain unknown.

References

  1. Environmental Excursion Alert Threshold Breach Counter — tool.io

Similar or alternative tools

  • Temperature Daily Swing Tolerance Checker

    Integrate exact piecewise-linear daily temperature degree-hours outside caller center/band and retain measured swing; unlike RH range/slew, this is excursion magnitude×duration, not preservation safety.

  • RH Daily Fluctuation Tolerance Band Checker

    Audit observed full-day RH range and resolved maximum slew as distinct caller fluctuation criteria; unresolved intersample extremes remain unknown.

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies