K-Space Sampling Density

Screen uniformly distributed full radial spokes using ceil(πN/2) angular Nyquist coverage; golden-angle subsets and compressed-sensing reconstruction quality are not evaluated.

Description

A conventional two-dimensional radial angular criterion requires about πN/2 spokes for a matrix size N.

A conventional two-dimensional radial angular criterion requires about πN/2 spokes for a matrix size N. The integer plan rounds that estimate upward.

The tool returns nyquistSpokes (nyquist spokes); samplingFraction (sampling fraction); angularCriterionMet (angular criterion met). Input measurements and model parameters are supplied by the caller; the tool computes the stated summary rather than acquiring those measurements.

When to use K-Space Sampling Density

Use K-Space Sampling Density when you already have readoutMatrixSize, acquiredSpokes and want nyquistSpokes, samplingFraction, angularCriterionMet. This is useful for checking a supplied calculation, documenting a measurement convention, or comparing observations prepared on the same basis.

How to use K-Space Sampling Density and understand its results

  1. Enter readoutMatrixSize, acquiredSpokes using the field table below. Match the units, ordering and data boundaries described in the calculation.
  2. Run the tool after checking the stated bounds and matching paired observations or categories. A malformed request gives a tool error rather than a usable measurement.
  3. Read nyquistSpokes, samplingFraction, angularCriterionMet. Use the calculation and interpretation below to distinguish amounts, ratios, signs and decision flags where applicable.
  4. Review the supplied parameters and assumptions before using the result in a report or comparing it with another observation.
Input fieldMeaningValue type and boundsRequirement
readoutMatrixSizeReadout matrix sizeintegerRequired
acquiredSpokesAcquired spokesintegerRequired

Use positive integer matrix size and spoke count. Equality meets the criterion; a sampling fraction above one is retained.

required spokes = ceil(π×readoutMatrixSize/2); fraction = acquired/required

The symbols refer to the supplied quantities or generated values described above; unit conversions and comparison boundaries follow the stated implementation.

json
{
  "input": {
    "readoutMatrixSize": 128,
    "acquiredSpokes": 100
  },
  "output": {
    "nyquistSpokes": 202,
    "samplingFraction": 0.49504950495049505,
    "angularCriterionMet": false
  }
}

Limitations and assumptions

This nominal criterion assumes the stated radial geometry. Variable density, half-spokes and reconstruction behavior are not assessed.

Numerical inputs must be finite. The tool checks its declared input shape and calculation constraints; those checks do not verify the quality, calibration or representativeness of the supplied observations.

Alternative or Complementary methods

Radial K-Space Trajectory: Generate explicit radial k-space spoke coordinates from supplied angles and signed radial sample locations; no trajectory density compensation is inferred. Compressed Sensing Acceleration: Measure actual 2D sampling-mask acceleration and audit required calibration coverage; mask sparsity is not a compressed-sensing reconstructability guarantee.

Methodological background: RAD229: MRI signal and sequence lecture notes.1

References

  1. RAD229: MRI signal and sequence lecture notes — Brian Hargreaves and colleagues, Stanford University

Similar or alternative tools

  • Radial K-Space Trajectory

    Generate explicit radial k-space spoke coordinates from supplied angles and signed radial sample locations; no trajectory density compensation is inferred.

  • Compressed Sensing Acceleration

    Measure actual 2D sampling-mask acceleration and audit required calibration coverage; mask sparsity is not a compressed-sensing reconstructability guarantee.