Diesel Dilution Ventilation Calculator
Audit observed DieselTracer tracer traverse concentrations/flow to infer actual source before caller steady dilution comparison, unlike existing supplied-source generic max-flow model; no ventilation setting or mine safety clearance. Caller independently verifies units, applicability and matching conditions; no operational recipe, safety certification, causal efficacy or legal/resource classification is inferred.
Description
A measured diesel-tracer concentration change across an air traverse can infer a source rate under a steady matched-flow model.
A measured diesel-tracer concentration change across an air traverse can infer a source rate under a steady matched-flow model.1
Comparing that source with a supplied outlet limit requires the inlet concentration and a positive permitted margin.
When to use Diesel Dilution Ventilation Calculator
Use this tool to calculate or review the supplied observations under the stated rules. Match completed survey or ledger observations by block, segment or stage and confirm their units and boundaries.
How to use Diesel Dilution Ventilation Calculator and understand its results
- Match completed survey or ledger observations by block, segment or stage and confirm their units and boundaries.
- Enter observedDieselTracerTraverseFlowsM3Second, observedDieselTracerInletConcentrations, observedDieselTracerOutletConcentrations, callerDieselTracerPermittedOutletConcentrations, using the field meanings and rules below, then run the tool.
- Read inferredMeasuredSourceRates, steadyModelRequiredFlowsM3Second. Inspect nested result fields where present, and review unknown records separately from known matches.
- Correct any reported input issue and run again. Before using a successful result, check the stated units, signs, reference scope and observation coverage.
| Input field | Meaning | Value type | Requirement |
|---|---|---|---|
| observedDieselTracerTraverseFlowsM3Second | Observed diesel tracer traverse flows m3 second | list of number | Required |
| observedDieselTracerInletConcentrations | Observed diesel tracer inlet concentrations | list of number | Required |
| observedDieselTracerOutletConcentrations | Observed diesel tracer outlet concentrations | list of number | Required |
| callerDieselTracerPermittedOutletConcentrations | Caller diesel tracer permitted outlet concentrations | list of number | Required |
Use aligned positive measured flow and nonnegative inlet, outlet and permitted concentrations in one consistent concentration basis. Require outlet≥inlet and permitted>inlet. Infer source=flow×(outlet−inlet), then requiredFlow=source/(permitted−inlet). Source units follow the concentration basis; no limit is chosen by the tool.
source_i=flow_i(outlet_i−inlet_i); requiredFlow_i=source_i/(permitted_i−inlet_i) Use the matching field units and the exact boundary, ordering and reference rules above.
| Output field | Meaning | Value type |
|---|---|---|
| inferredMeasuredSourceRates | Inferred measured source rates | list of number |
| steadyModelRequiredFlowsM3Second | Steady model required flows m3 second | list of number |
{
"input": {
"observedDieselTracerTraverseFlowsM3Second": [
10,
20
],
"observedDieselTracerInletConcentrations": [
1,
1
],
"observedDieselTracerOutletConcentrations": [
2,
3
],
"callerDieselTracerPermittedOutletConcentrations": [
3,
5
]
},
"output": {
"inferredMeasuredSourceRates": [
10,
40
],
"steadyModelRequiredFlowsM3Second": [
5,
10
]
}
} Limitations and assumptions
Units, ledger boundaries, survey interpretation and model applicability must be independently established. These summaries do not assign reserve/resource classifications or establish support adequacy, ventilation safety or an operating setting.
Missing required fields, unknown fields, wrong types and violated rules return input issues. Numeric values and outputs must be finite. Lists and matrices must be dense, without missing cells. Numeric lists allow at most 10000 entries; ordinary string lists allow at most 128 strings of 128 UTF-16 units each; numeric matrices allow at most 128 rows and 128 columns, subject to narrower requirements above.
Alternative or Complementary methods
For a related step, use Dust Dilution Ventilation Calculator: A measured dust concentration change across an air traverse can infer a source rate under a steady matched-flow model. For a complementary comparison, use Ventilation Air Velocity Calculator: An air traverse integrates signed normal velocity across sampled duct cells.
References
-
Diesel Dilution Ventilation Calculator — tool.io
Similar or alternative tools
- Dust Dilution Ventilation Calculator
A measured dust concentration change across an air traverse can infer a source rate under a steady matched-flow model.
- Ventilation Air Velocity Calculator
An air traverse integrates signed normal velocity across sampled duct cells.