Skip to content

Main content

Microcontroller: Timer Prescaler Register Minus One Tool

Encode an explicitly declared timer divide-by-(register+1) prescaler, validating register capacity; does not assume this convention applies to every microcontroller.

Loading tool…

Description

Return divisor minus one as registerValue.

Timer formulas depend on whether endpoints are inclusive, the count direction, prescaling, and wrap behavior. A counter reading alone cannot reveal an arbitrary number of elapsed wraps.

Return divisor minus one as registerValue.

When to use this tool

Use Microcontroller: Timer Prescaler Register Minus One when you need a timer period, wrap delta, or explicit count-budget term.

How to use the tool and how it works

  1. Enter prescalerDivisor, registerBits. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read result. Expand result to inspect the returned fields.

Require registerBits from 1 through 32 and prescalerDivisor from one through 2^registerBits. Return divisor minus one as registerValue.1

Input fieldMeaning and unitsAccepted input
prescalerDivisorPrescaler DivisorRequired. Safe integer.
registerBitsRegister BitsRequired. Safe integer.
Output fieldInterpretationReturned shape
resultResultRequired. Object.
result.registerValueRegister ValueCalculated result member: number.
json
{
  "input": {
    "prescalerDivisor": 16,
    "registerBits": 8
  },
  "output": {
    "result": {
      "registerValue": 15
    }
  }
}

Limitations and assumptions

  • This assumes a minus-one register encoding; actual register layout and device support must be checked independently.
  • Outputs are nested inside result. Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Check the timer mode and register semantics in the device documentation, including synchronization and latency.

References

  1. Calculation and input contract: microcontroller/timer-prescaler-register-minus-one — tool.io

Similar or alternative tools