TIC Area
Integrate a total-ion chromatogram using trapezoidal area.
Description
Chromatogram area integrates signal over time, while peak intensity reports the largest sampled value.
Chromatogram area integrates signal over time, while peak intensity reports the largest sampled value. Unequal sampling intervals can be handled by trapezoidal integration.1
Integrate a total-ion chromatogram using trapezoidal area.
When to use TIC Area
Use this tool to integrate a total-ion chromatogram using trapezoidal area.
Prepare the measured profile, formula counts, upstream model outputs or caller-defined reference criteria requested. Keep paired entries aligned and units, sample basis and preprocessing consistent.
How to use TIC Area and understand its results
- Prepare the measured profile, formula counts, upstream model outputs or caller-defined reference criteria requested. Keep paired entries aligned and units, sample basis and preprocessing consistent.
- Enter timesMinutes, totalIonIntensities using the field table and calculation rules, then run the tool.
- Read area, peakIntensity. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| timesMinutes | Times minutes | list of number | Required |
| totalIonIntensities | Total ion intensities | list of number | Required |
Enter at least two aligned strictly increasing times in minutes and nonnegative intensities. Return area in intensity×minutes and maximum sampled intensity.
area=Σ(time_i−time_(i−1))×(signal_i+signal_(i−1))/2 Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| area | Area | number |
| peakIntensity | Peak intensity | number |
{
"input": {
"timesMinutes": [
0,
1,
2
],
"totalIonIntensities": [
0,
10,
0
]
},
"output": {
"area": 10,
"peakIntensity": 10
}
} Limitations and assumptions
No baseline correction, peak boundaries or interpolation beyond linear trapezoids is provided.
Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Lists are limited to 100,000 entries; the rules above may require smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.
Alternative or Complementary methods
Use TIC Signal Normalization: Scale a peak-area vector to a supplied total ion current. For a complementary task, use Peak FWHM: Interpolate chromatographic full width at half maximum.
References
-
TIC Area — tool.io
Similar or alternative tools
- TIC Signal Normalization
Scale a peak-area vector to a supplied total ion current.
- Peak FWHM
Interpolate chromatographic full width at half maximum.