NMR Reference Offset

Re-reference NMR chemical shifts to observed TMS zero.

Description

Chemical-shift referencing applies a constant offset so a measured TMS reference is placed at zero ppm.

Chemical-shift referencing applies a constant offset so a measured TMS reference is placed at zero ppm. Every supplied shift receives the same translation.1

Re-reference NMR chemical shifts to observed TMS zero.

When to use NMR Reference Offset

Use this tool to re-reference NMR chemical shifts to observed TMS zero.

Prepare the measured profile, formula counts, upstream model outputs or caller-defined reference criteria requested. Keep paired entries aligned and units, sample basis and preprocessing consistent.

How to use NMR Reference Offset and understand its results

  1. Prepare the measured profile, formula counts, upstream model outputs or caller-defined reference criteria requested. Keep paired entries aligned and units, sample basis and preprocessing consistent.
  2. Enter observedTmsPpm, measuredShiftsPpm using the field table and calculation rules, then run the tool.
  3. Read referenceOffsetPpm, correctedShiftsPpm. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
observedTmsPpmObserved tms ppmnumberRequired
measuredShiftsPpmMeasured shifts ppmlist of numberRequired

Enter finite observed reference and shift list, which may be empty. Return the offset and shifted values in input order.

offset=−observedTMSppm; corrected_i=shift_i+offset

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
referenceOffsetPpmReference offset ppmnumber
correctedShiftsPpmCorrected shifts ppmlist of number
json
{
  "input": {
    "observedTmsPpm": 0.2,
    "measuredShiftsPpm": [
      1.2,
      2.2
    ]
  },
  "output": {
    "referenceOffsetPpm": -0.2,
    "correctedShiftsPpm": [
      1,
      2
    ]
  }
}

Limitations and assumptions

No peak detection, reference identity check or frequency-dependent calibration is performed.

Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Lists are limited to 100,000 entries; the rules above may require smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use NMR Coupling From PPM: Convert NMR peak separation in ppm to J-coupling hertz at a field frequency. For a complementary task, use NMR Bucket Integrals: Bin NMR spectral integrals by configurable chemical-shift width.

References

  1. NMR Reference Offset — tool.io