Spring Turnover Trigger Temperature Checker

Screen sampled near-isothermal ice-free water against explicit caller spring turnover temperature/spread tolerance; temperature similarity does not prove mixing, adequate wind or complete water-column coverage.

Description

Near-isothermal temperature evidence can identify a spring-turnover candidate.

Near-isothermal temperature evidence can identify a spring-turnover candidate. Ice status and sampled reference proximity are additional gates.1

Enter at least two temperatures0–40°C, finite reference, nonnegative tolerances and ice-cover flag. Return spread, proximity flag and candidate flag.

When to use Spring Turnover Trigger Temperature Checker

Use Spring Turnover Trigger Temperature Checker when you need to evaluate the supplied records under the calculation and evidence rules below. Similarity does not prove mixing, adequate wind or complete depth coverage; no universal trigger temperature is supplied.

Prepare the observed lake or sample measurements and explicit calibration, reference values or thresholds requested. Keep depth coverage, units, dates and sampling conditions consistent.

How to use Spring Turnover Trigger Temperature Checker and understand its results

  1. Prepare the observed lake or sample measurements and explicit calibration, reference values or thresholds requested. Keep depth coverage, units, dates and sampling conditions consistent.
  2. Enter observedWaterTemperaturesC, callerIsothermalSpreadToleranceC, callerTurnoverReferenceTemperatureC, callerReferenceToleranceC, iceCoverStillPresent using the field table and calculation rules, then run the tool.
  3. Read observedColumnTemperatureSpreadC, nearCallerReferenceTemperature, isothermalIceFreeTurnoverCandidate. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
observedWaterTemperaturesCObserved water temperatures clist of numberRequired
callerIsothermalSpreadToleranceCCaller isothermal spread tolerance cnumberRequired
callerTurnoverReferenceTemperatureCCaller turnover reference temperature cnumberRequired
callerReferenceToleranceCCaller reference tolerance cnumberRequired
iceCoverStillPresentIce cover still presentbooleanRequired

Enter at least two temperatures0–40°C, finite reference, nonnegative tolerances and ice-cover flag. Return spread, proximity flag and candidate flag.

candidate=iceFree AND all abs(temperature−reference)≤referenceTolerance AND spread≤spreadTolerance

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
observedColumnTemperatureSpreadCObserved column temperature spread cnumber
nearCallerReferenceTemperatureNear caller reference temperatureboolean
isothermalIceFreeTurnoverCandidateIsothermal ice free turnover candidateboolean
json
{
  "input": {
    "observedWaterTemperaturesC": [
      3.9,
      4,
      4.1
    ],
    "callerIsothermalSpreadToleranceC": 0.3,
    "callerTurnoverReferenceTemperatureC": 4,
    "callerReferenceToleranceC": 0.2,
    "iceCoverStillPresent": false
  },
  "output": {
    "observedColumnTemperatureSpreadC": 0.19999999999999973,
    "nearCallerReferenceTemperature": true,
    "isothermalIceFreeTurnoverCandidate": true
  }
}

Limitations and assumptions

Similarity does not prove mixing, adequate wind or complete depth coverage; no universal trigger temperature is supplied.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Numeric lists are limited to 10,000 entries; string lists to 128 strings of at most 128 characters each. The rules above may impose smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.

Alternative or Complementary methods

Use Inverse Stratification Under Ice Checker: Under-ice inverse temperature evidence requires sampled warming with depth within 0–4°C. Measurement tolerance determines resolved change. For a complementary task, use Relative Thermal Resistance Mixing Calculator: Relative thermal resistance normalizes a density contrast by a declared reference contrast. Its sign retains stable versus reversed ordering.

References

  1. Spring Turnover Trigger Temperature Checker — tool.io

Similar or alternative tools

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies