Dissolved Oxygen Saturation Altitude Temp Calculator

Approximate pure-freshwater oxygen saturation using bounded temperature cubic and dry-air station-pressure ratio; caller supplies actual pressure already altitude-resolved, not geodesy, exact standard solubility, salinity correction or observed deficit.

Description

Freshwater oxygen saturation depends on temperature and air pressure.

Freshwater oxygen saturation depends on temperature and air pressure. Station pressure already incorporates the caller’s altitude conditions.1

Enter temperature0–30°C and positive station pressure≤110 kPa above modeled vapor pressure. Compute vapor=0.61078exp(17.2694T/(T+237.29)); return approximate saturation and vapor pressure.

When to use Dissolved Oxygen Saturation Altitude Temp Calculator

Use Dissolved Oxygen Saturation Altitude Temp Calculator when you need to evaluate the supplied records under the calculation and evidence rules below. This bounded cubic is not an exact solubility standard, salinity correction, altitude conversion or observed oxygen deficit.

Prepare the observed lake or sample measurements and explicit calibration, reference values or thresholds requested. Keep depth coverage, units, dates and sampling conditions consistent.

How to use Dissolved Oxygen Saturation Altitude Temp Calculator and understand its results

  1. Prepare the observed lake or sample measurements and explicit calibration, reference values or thresholds requested. Keep depth coverage, units, dates and sampling conditions consistent.
  2. Enter waterTemperatureC, measuredStationPressureKpa using the field table and calculation rules, then run the tool.
  3. Read approxFreshwaterOxygenSaturationMgLiter, approxWaterVaporPressureKpa. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
waterTemperatureCWater temperature cnumberRequired
measuredStationPressureKpaMeasured station pressure kpanumberRequired

Enter temperature0–30°C and positive station pressure≤110 kPa above modeled vapor pressure. Compute vapor=0.61078exp(17.2694T/(T+237.29)); return approximate saturation and vapor pressure.

standard=14.621−0.41022T+0.007991T²−0.000077774T³; saturation=standard(P−vapor)/(101.325−vapor)

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
approxFreshwaterOxygenSaturationMgLiterApprox freshwater oxygen saturation mg liternumber
approxWaterVaporPressureKpaApprox water vapor pressure kpanumber
json
{
  "input": {
    "waterTemperatureC": 20,
    "measuredStationPressureKpa": 90
  },
  "output": {
    "approxFreshwaterOxygenSaturationMgLiter": 7.962176720345409,
    "approxWaterVaporPressureKpa": 2.3382176476385186
  }
}

Limitations and assumptions

This bounded cubic is not an exact solubility standard, salinity correction, altitude conversion or observed oxygen deficit.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use Reaeration Coefficient Oxygen Transfer Calculator: Constant first-order reaeration approaches a specified saturation concentration exponentially. Supersaturated water can yield signed oxygen loss. For a complementary task, use Hypolimnetic Oxygen Demand Rate Calculator: Oxygen demand can be inferred from inventory change after subtracting independently measured advection. A negative result indicates net nonadvective replenishment.

References

  1. Dissolved Oxygen Saturation Altitude Temp Calculator — tool.io