Beam-Tap Ratio

Calculate calibrated beam-monitor tap ratio and measured sample share.

Description

A beam-monitor tap ratio compares sample power with a reference and applies a supplied calibration factor.

A beam-monitor tap ratio compares sample power with a reference and applies a supplied calibration factor. The sample-share percentage uses the uncalibrated sum instead.1

Calculate calibrated beam-monitor tap ratio and measured sample share.

When to use Beam-Tap Ratio

Use this tool to calculate calibrated beam-monitor tap ratio and measured sample share.

Prepare the optical measurements, geometry, fitted coefficients or caller-selected thresholds requested. Confirm wavelength, radius/diameter, pulse-width, angle and unit conventions before running the calculation.

How to use Beam-Tap Ratio and understand its results

  1. Prepare the optical measurements, geometry, fitted coefficients or caller-selected thresholds requested. Confirm wavelength, radius/diameter, pulse-width, angle and unit conventions before running the calculation.
  2. Enter samplePowerWatts, referencePowerWatts, calibrationFactor using the field table and calculation rules, then run the tool.
  3. Read calibratedTapRatio, sampleSharePercent. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
samplePowerWattsSample tap power (W)number; minimum: 0Required
referencePowerWattsReference power (W)number; minimum: 0Required
calibrationFactorTap calibration factornumber; minimum: 0Required

Enter nonnegative sample/factor and positive reference watts. Return ratio and share.

calibratedRatio=sample/reference×factor; share%=100sample/(sample+reference)

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
calibratedTapRatioCalibrated sample/reference rationumber; minimum: 0
sampleSharePercentSample share of measured total (%)number; minimum: 0; maximum: 100
json
{
  "input": {
    "samplePowerWatts": 2,
    "referencePowerWatts": 8,
    "calibrationFactor": 1
  },
  "output": {
    "calibratedTapRatio": 0.25,
    "sampleSharePercent": 20
  }
}

Limitations and assumptions

No detector linearity, calibration fitting or optical splitter model is supplied.

Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use Brightness Conservation: Measure brightness retention through a tapered double-clad section against a caller limit. For a complementary task, use Cantilever Photoacoustic Gain: Compare cantilever and baseline photoacoustic signal and SNR.

References

  1. Beam-Tap Ratio — tool.io

Similar or alternative tools

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies