Ablation Sampling Area
Estimate gross and nonoverlapping area sampled by a sequence of ablation pulses.
Description
Ablation sampling area multiplies circular spot area by pulse count.
Ablation sampling area multiplies circular spot area by pulse count. A supplied new-area fraction reduces the gross total for overlap.1
Estimate gross and nonoverlapping area sampled by a sequence of ablation pulses.
When to use Ablation Sampling Area
Use this tool to estimate gross and nonoverlapping area sampled by a sequence of ablation pulses.
Prepare the optical measurements, geometry, fitted coefficients or caller-selected thresholds requested. Confirm wavelength, radius/diameter, pulse-width, angle and unit conventions before running the calculation.
How to use Ablation Sampling Area and understand its results
- Prepare the optical measurements, geometry, fitted coefficients or caller-selected thresholds requested. Confirm wavelength, radius/diameter, pulse-width, angle and unit conventions before running the calculation.
- Enter spotDiameterMicrometers, pulseCount, newAreaFractionPerPulse using the field table and calculation rules, then run the tool.
- Read singleSpotAreaSquareMicrometers, grossSampledAreaSquareMicrometers, effectiveNewAreaSquareMicrometers. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| spotDiameterMicrometers | Ablation spot diameter (µm) | number; minimum: 0 | Required |
| pulseCount | Pulse count | integer; minimum: 0 | Required |
| newAreaFractionPerPulse | New-area fraction per pulse | number; minimum: 0; maximum: 1 | Required |
Enter nonnegative diameter µm, nonnegative integer pulses and fraction 0–1. Return all areas in µm².
spotArea=π(d/2)²; gross=spotArea×count; newArea=gross×fraction Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| singleSpotAreaSquareMicrometers | Single-spot area (µm²) | number; minimum: 0 |
| grossSampledAreaSquareMicrometers | Gross sampled area (µm²) | number; minimum: 0 |
| effectiveNewAreaSquareMicrometers | Effective new area (µm²) | number; minimum: 0 |
{
"input": {
"spotDiameterMicrometers": 2,
"pulseCount": 10,
"newAreaFractionPerPulse": 0.5
},
"output": {
"singleSpotAreaSquareMicrometers": 3.141592653589793,
"grossSampledAreaSquareMicrometers": 31.41592653589793,
"effectiveNewAreaSquareMicrometers": 15.707963267948966
}
} Limitations and assumptions
No actual spot intersection, scan geometry or removal depth is calculated. The same fraction applies even to the first pulse.
Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.
Alternative or Complementary methods
Use Ablation Threshold Fit: Fit a Liu ablation-threshold line from pulse energy and squared crater radius. For a complementary task, use Assist-Gas Cost Comparison: Compare caller-supplied assist-gas consumption and rework costs.
References
-
Ablation Sampling Area — tool.io
Similar or alternative tools
- Ablation Threshold Fit
Fit a Liu ablation-threshold line from pulse energy and squared crater radius.
- Assist-Gas Cost Comparison
Compare caller-supplied assist-gas consumption and rework costs.