LED Cost Per DLI Delivered

Compare electrical and allocated fixture costs per delivered canopy photon mole and per DLI unit using supplied efficacy/delivery; canopy area distinguishes total photons from areal dose.

Description

Lighting cost per delivered photon differs from cost per areal daily light integral.

Lighting cost per delivered photon differs from cost per areal daily light integral. Canopy area links total photon moles to dose per square meter.1

Compare electrical and allocated fixture costs per delivered canopy photon mole and per DLI unit using supplied efficacy/delivery; canopy area distinguishes total photons from areal dose.

When to use LED Cost Per DLI Delivered

Use this tool to compare electrical and allocated fixture costs per delivered canopy photon mole and per DLI unit using supplied efficacy/delivery; canopy area distinguishes total photons from areal dose.

Prepare the plant, nutrient, light or scheduling measurements for the intended crop and period. Keep paired records aligned and confirm units and supplied target values.

How to use LED Cost Per DLI Delivered and understand its results

  1. Prepare the plant, nutrient, light or scheduling measurements for the intended crop and period. Keep paired records aligned and confirm units and supplied target values.
  2. Enter lampElectricalWatts, photonEfficacyMicromolesPerJoule, canopyDeliveryFraction, canopyAreaM2, dailyOnHours, electricityCostPerKwh, dailyAllocatedFixtureCost using the field table and calculation rules, then run the tool.
  3. Read deliveredDailyLightIntegral, dailyElectricalKwh, dailyTotalLightingCost, costPerDeliveredMole, costPerDliUnit. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
lampElectricalWattsLamp electrical wattsnumberRequired
photonEfficacyMicromolesPerJoulePhoton efficacy micromoles per joulenumberRequired
canopyDeliveryFractionCanopy delivery fractionnumberRequired
canopyAreaM2Canopy area m2numberRequired
dailyOnHoursDaily on hoursnumberRequired
electricityCostPerKwhElectricity cost per kwhnumberRequired
dailyAllocatedFixtureCostDaily allocated fixture costnumberRequired

Use positive power, efficacy, canopy area and delivery fraction in (0,1], operating hours in (0,24], and nonnegative electricity/fixture costs in one currency. Compute kWh, total daily cost, delivered DLI and both cost denominators.

delivered moles=watts × efficacy μmol/J × delivery × hours × 0.0036; DLI=moles/area

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
deliveredDailyLightIntegralDelivered daily light integralnumber
dailyElectricalKwhDaily electrical kwhnumber
dailyTotalLightingCostDaily total lighting costnumber
costPerDeliveredMoleCost per delivered molenumber
costPerDliUnitCost per dli unitnumber
json
{
  "input": {
    "lampElectricalWatts": 100,
    "photonEfficacyMicromolesPerJoule": 2,
    "canopyDeliveryFraction": 0.5,
    "canopyAreaM2": 2,
    "dailyOnHours": 10,
    "electricityCostPerKwh": 0.2,
    "dailyAllocatedFixtureCost": 0.1
  },
  "output": {
    "deliveredDailyLightIntegral": 1.8,
    "dailyElectricalKwh": 1,
    "dailyTotalLightingCost": 0.30000000000000004,
    "costPerDeliveredMole": 0.08333333333333334,
    "costPerDliUnit": 0.16666666666666669
  }
}

Limitations and assumptions

Efficacy and delivery are supplied. Tariffs, crop response and fixture performance are not fetched or validated.

Numeric inputs and returned numeric values must be finite; an unrepresentable returned value produces an error. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use Supplemental Light Shortfall Hours: Invert measured natural-light deficit into supplementary hours with delivery loss and a caller available photoperiod; unmet photon budget is explicit, not a crop lighting recommendation. For a complementary task, use Daily Light Integral MOL M2 Day: Integrate measured time-varying PPFD by trapezoids into observed daily photon dose; unobserved hours are not silently filled and a constant PPFD-to-DLI alias is excluded.

References

  1. LED Cost Per DLI Delivered — tool.io

Similar or alternative tools

  • Supplemental Light Shortfall Hours

    Invert measured natural-light deficit into supplementary hours with delivery loss and a caller available photoperiod; unmet photon budget is explicit, not a crop lighting recommendation.

  • Daily Light Integral MOL M2 Day

    Integrate measured time-varying PPFD by trapezoids into observed daily photon dose; unobserved hours are not silently filled and a constant PPFD-to-DLI alias is excluded.

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies