Cannon Pinion Setting Force Threshold Screen

Screen a measured crown pull force against explicit service-specific minimum and maximum values; it does not derive a universal cannon-pinion torque.

Description

A setting-force window compares measured crown pull with service-specific bounds.

A setting-force window compares measured crown pull with service-specific bounds. Force is distinct from cannon-pinion torque.1

Screen a measured crown pull force against explicit service-specific minimum and maximum values; it does not derive a universal cannon-pinion torque.

When to use Cannon Pinion Setting Force Threshold Screen

Use this tool to screen a measured crown pull force against explicit service-specific minimum and maximum values; it does not derive a universal cannon-pinion torque.

Choose a supported reference focus or prepare the watch measurements, evidence and explicit limits requested. Confirm units and date conventions before running.

How to use Cannon Pinion Setting Force Threshold Screen and understand its results

  1. Choose a supported reference focus or prepare the watch measurements, evidence and explicit limits requested. Confirm units and date conventions before running.
  2. Enter maximumAllowedPullForceNewtons, measuredPullForceNewtons, minimumAllowedPullForceNewtons using the field table and calculation rules, then run the tool.
  3. Read forceAboveMinimumNewtons, forceBelowMaximumNewtons, withinCallerForceWindow. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
maximumAllowedPullForceNewtonsMaximum allowed pull force (N)number; minimum: 0Required
measuredPullForceNewtonsMeasured crown pull force (N)number; minimum: 0Required
minimumAllowedPullForceNewtonsMinimum allowed pull force (N)number; minimum: 0Required

Enter nonnegative measured/minimum N and positive maximum with minimum≤maximum. Return signed margins and inclusive window flag.

margins=measured−minimum, maximum−measured; pass=both≥0

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
forceAboveMinimumNewtonsForce above minimum (N)number
forceBelowMaximumNewtonsForce below maximum (N)number
withinCallerForceWindowWithin caller force windowboolean
json
{
  "input": {
    "measuredPullForceNewtons": 8,
    "minimumAllowedPullForceNewtons": 5,
    "maximumAllowedPullForceNewtons": 10
  },
  "output": {
    "forceAboveMinimumNewtons": 3,
    "forceBelowMaximumNewtons": 2,
    "withinCallerForceWindow": true
  }
}

Limitations and assumptions

No universal force target, torque conversion or adjustment is supplied.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.

Alternative or Complementary methods

Use Beat Error Symmetry Threshold Screen: Screen two beat-error observations against explicit caller-supplied magnitude and relative-difference limits; this is not a certification decision. For a complementary task, use Amplitude Explicit Threshold Screen: Screen measured balance amplitude against explicit caller-supplied minimum and maximum values without applying a universal healthy-degree target.

References

  1. Cannon Pinion Setting Force Threshold Screen — tool.io

Similar or alternative tools

  • Beat Error Symmetry Threshold Screen

    Screen two beat-error observations against explicit caller-supplied magnitude and relative-difference limits; this is not a certification decision.

  • Amplitude Explicit Threshold Screen

    Screen measured balance amplitude against explicit caller-supplied minimum and maximum values without applying a universal healthy-degree target.

Don't forget to set a bookmark for tool.io!