Outline Deviation Symmetry Check
Audit corresponding measured outline points about caller already-aligned mirror axis, preserving pair deviations; no automatic alignment, mineral shape ideal or inferred optical symmetry.
Description
Mirror-outline comparison requires already aligned corresponding points.
Mirror-outline comparison requires already aligned corresponding points. For a declared y-axis mirror, x coordinates reverse sign while y coordinates agree.1
Audit corresponding measured outline points about caller already-aligned mirror axis, preserving pair deviations; no automatic alignment, mineral shape ideal or inferred optical symmetry.
When to use Outline Deviation Symmetry Check
Use this tool to audit corresponding measured outline points about caller already-aligned mirror axis, preserving pair deviations; no automatic alignment, mineral shape ideal or inferred optical symmetry.
Prepare the gemstone measurements, spectra or comparison data and any supplied calibration parameters. Check units, reference conditions and record alignment.
How to use Outline Deviation Symmetry Check and understand its results
- Prepare the gemstone measurements, spectra or comparison data and any supplied calibration parameters. Check units, reference conditions and record alignment.
- Enter pairedOutlinePointsMm, callerMirrorDeviationToleranceMm using the field table and calculation rules, then run the tool.
- Read pairMirrorDeviationDistancesMm, maximumMeasuredMirrorDeviationMm, aboveCallerOutlineTolerance. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| pairedOutlinePointsMm | Paired outline points mm | list of list of number | Required |
| callerMirrorDeviationToleranceMm | Caller mirror deviation tolerance mm | number | Required |
Enter a nonempty even number of consecutive 2D point pairs in mm and nonnegative tolerance. Compare each pair under y-axis reflection and return all deviations, their maximum and a strict above-tolerance flag.
pair error=hypot(x1+x2,y1−y2) Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| pairMirrorDeviationDistancesMm | Pair mirror deviation distances mm | list of number |
| maximumMeasuredMirrorDeviationMm | Maximum measured mirror deviation mm | number |
| aboveCallerOutlineTolerance | Above caller outline tolerance | boolean |
{
"input": {
"pairedOutlinePointsMm": [
[
1,
2
],
[
-1,
2
],
[
2,
3
],
[
-2.1,
3
]
],
"callerMirrorDeviationToleranceMm": 0.05
},
"output": {
"pairMirrorDeviationDistancesMm": [
0,
0.10000000000000009
],
"maximumMeasuredMirrorDeviationMm": 0.10000000000000009,
"aboveCallerOutlineTolerance": true
}
} Limitations and assumptions
No automatic registration or ideal mineral shape is inferred. Optical symmetry is a separate measurement.
Numeric inputs and returned numeric values must be finite; an unrepresentable returned value produces an error. Matrices are limited to 128 rows and 128 entries per row; other numeric lists are limited to 100,000 entries. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.
Alternative or Complementary methods
Use Pearl Shape Symmetry Rater: Audit centered pearl outline through principal second-moment axes and radial RMS residual, distinct from paired mirror errors; sampling must be comparable, not a pearl shape/market grade or 3D reconstruction. For a complementary task, use Optical Symmetry Score: Audit aligned image brightness asymmetry about declared horizontal/vertical mirror axes, normalized to total flux; unlike paired physical outline error, illumination/registration remain confounders and no automatic alignment.
References
-
Outline Deviation Symmetry Check — tool.io
Similar or alternative tools
- Pearl Shape Symmetry Rater
Audit centered pearl outline through principal second-moment axes and radial RMS residual, distinct from paired mirror errors; sampling must be comparable, not a pearl shape/market grade or 3D reconstruction.
- Optical Symmetry Score
Audit aligned image brightness asymmetry about declared horizontal/vertical mirror axes, normalized to total flux; unlike paired physical outline error, illumination/registration remain confounders and no automatic alignment.