Fixed Sync Frame Boundary Finder

Find all overlapping occurrences of an explicit sync byte sequence; occurrences are candidate boundaries, not validated frames.

Description

Find all overlapping occurrences of an explicit sync byte sequence; occurrences are candidate boundaries, not validated frames.

A synchronization token may occur at overlapping positions in a byte stream. Reporting every literal match exposes those possibilities.

When to use this tool

Find all overlapping occurrences of an explicit sync byte sequence; occurrences are candidate boundaries, not validated frames.

  • Prepare the supplied bytes, sync fields for this operation.
  • Compare the complete example with the representation used by your own input before carrying the result into another step.

How to use the tool and how it works

  1. Enter bytes, sync. Use the exact text syntax, units and index conventions explained below.
  2. Run the tool. If input validation fails, correct the supplied fields before interpreting any result.
  3. Read result.positions. Interpret false, null and empty lists using the distinctions below; they can be valid outputs.

Require a nonempty sync byte list. At each zero-based bytes position test the complete sync sequence and return all matching starts, including overlaps.1

Input fieldMeaning and representationAccepted input
bytesbytes.List of integers from 0 to 255; at most 128 bytes
syncsync.List of integers from 0 to 255; at most 128 bytes
Output fieldInterpretation
resultObject containing the named outputs below.
result.positionsThe positions list in the ordering and representation described above.
json
{
  "input": {
    "bytes": [
      1,
      1,
      1,
      2
    ],
    "sync": [
      1,
      1
    ]
  },
  "output": {
    "result": {
      "positions": [
        0,
        1
      ]
    }
  }
}

Limitations and assumptions

  • These are candidate synchronization positions, not validated frame boundaries. Payload coincidences and protocol length rules are not resolved.
  • All declared input fields are required and unexpected top-level fields are rejected. Numbers must be finite; lists are limited to 128 entries and ordinary text fields to 8,192 UTF-16 code units, with tighter limits where stated.
  • JSON text inputs must parse within bounded nesting and size limits. Numeric outputs outside the safe finite range are rejected; large exact integer results use decimal strings. Indexes and half-open spans are zero-based unless a rank is explicitly described as one-based.

Alternative or Complementary methods

Use a stateful protocol parser when processing partial streams or validating complete packets. Retain the declared prefix width, byte order and payload-versus-frame boundary convention when composing these operations.

References

  1. Tool behavior and example: Fixed Sync Frame Boundary Finder — tool.io

Similar or alternative tools

  • Byte Frame Chunk Carry Tool

    Advance one fixed-byte streaming frame chunk with explicit incomplete carry, emitting complete frames and retaining the new tail; no sync search.

  • Byte Frame Chunk Rejoin Tool

    Rejoin explicit bounded byte chunks and report each chunk’s half-open source span, preserving empty-chunk provenance.

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies