Description
Floor-divide onset-minus-origin for cycleIndex and return nonnegative modular position and phase fraction.
Cyclic musical positions need a cycle length, origin and tie policy. Negative positions and half-cycle differences require careful modular conventions, especially when returning both a local phase and a whole-cycle carry.
Floor-divide onset-minus-origin for cycleIndex and return nonnegative modular position and phase fraction.
When to use this tool
Use Beat Cycle Onset Position Wrap when you need an explicit rhythmic or tuning-cycle coordinate calculation.
How to use the tool and how it works
- Enter onsetPulses, cyclePulses, originPulses. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read cycleIndex, position, phaseFraction. Use the output convention below.
Require positive cyclePulses. Floor-divide onset-minus-origin for cycleIndex and return nonnegative modular position and phase fraction.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| onsetPulses | Onset Pulses | Required. Finite number. |
| cyclePulses | Cycle Pulses | Required. Finite number; strictly above 0. |
| originPulses | Origin Pulses | Required. Finite number. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| cycleIndex | Cycle Index | Required. Safe integer. |
| position | Position | Required. Finite number. |
| phaseFraction | Phase Fraction | Required. Finite number. |
{
"input": {
"onsetPulses": 17,
"cyclePulses": 8,
"originPulses": 1
},
"output": {
"cycleIndex": 2,
"position": 0,
"phaseFraction": 0
}
} Limitations and assumptions
- Pulse coordinates may be fractional and cycles need not be integer length. The operation does not detect beats, classify meter or edit a recording.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use the intended musical notation and source annotations to establish the cycle and origin. A numerical wrap cannot determine meter, tuning practice or cultural meaning by itself.
References
Similar or alternative tools
- Public Rhythm Cycle Phase Shift
Add with exact integer arithmetic, return nonnegative phase modulo length and floor-based cycle carry as safe numeric integers.
- Metrical Cycle Phase Gap
Compute exact modular second-minus-first beat gap; choose the nearest signed representative and resolve an exact half-cycle with positiveTie.