Description
Convert a concentration between supplied gas-volume bases while preserving amount.
Environmental inventories distinguish wet/dry material, analytical detection limits, gas-volume reference states, represented area and allocation weights. A monitoring completeness fraction can exceed one when extra records are present. Supplied conversion and allocation factors need separate justification before physical or environmental interpretation.
Convert a concentration between supplied gas-volume bases while preserving amount.
When to use this tool
Use Pollutant Standard Volume Concentration Factor when checking the stated environmental reporting, analytical, inventory or support convention.
How to use the tool and how it works
- Enter reportedConcentration, measuredGasVolume, suppliedStandardGasVolume. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read standardVolumeConcentration. Use the output convention below.
Require nonnegative concentration/measured gas volume and positive supplied standard gas volume. Return concentration*measuredVolume/standardVolume.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| reportedConcentration | Reported Concentration | Required. Finite number; minimum 0. |
| measuredGasVolume | Measured Gas Volume | Required. Finite number; minimum 0. |
| suppliedStandardGasVolume | Positive comparison-state volume for the same pollutant amount; no pressure/temperature convention inferred. | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| standardVolumeConcentration | Standard Volume Concentration | Required. Finite number. |
{
"input": {
"reportedConcentration": 10,
"measuredGasVolume": 120,
"suppliedStandardGasVolume": 100
},
"output": {
"standardVolumeConcentration": 12
}
} Limitations and assumptions
- Assumes conserved pollutant amount and compatible gas-volume bases; no pressure, temperature, moisture or standard-state conversion is inferred.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use calibrated representative measurements and appropriate complete analytical, spatial or life-cycle methods for actual environmental conclusions and compliance decisions.
References
Similar or alternative tools
- Wastewater Load Concentration Volume
Convert wastewater concentration in milligrams per litre and volume to total kilograms.
- Dust Lead Area Weight Crosswalk
Convert collected dust lead mass per sampled surface area to micrograms per square metre.