Description
Return inletMassRate = inletFlow*inletConcentration, outletMassRate = outletFlow*outletConcentration, removedMassRate = inletMassRate-outletMassRate and efficiency = 1-outletMassRate/inletMassRate.
A pollutant load combines concentration with a compatible flow, volume or activity factor. A load rate has amount-per-time units, whereas an integrated load also includes duration; concentration differences alone do not describe removal when flows differ.
Return inletMassRate = inletFlow*inletConcentration, outletMassRate = outletFlow*outletConcentration, removedMassRate = inletMassRate-outletMassRate and efficiency = 1-outletMassRate/inletMassRate.
When to use this tool
Use Dust Collector Inlet Outlet Mass Balance when checking one supplied emission, transport or treatment mass-balance contribution.
How to use the tool and how it works
- Enter inletFlow, inletConcentration, outletFlow, outletConcentration. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read inletMassRate, outletMassRate, removedMassRate, efficiency. Use the output convention below.
Require positive inletFlow and inletConcentration and nonnegative outletFlow and outletConcentration. Return inletMassRate = inletFlow*inletConcentration, outletMassRate = outletFlow*outletConcentration, removedMassRate = inletMassRate-outletMassRate and efficiency = 1-outletMassRate/inletMassRate.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| inletFlow | Inlet Flow | Required. Finite number; strictly above 0. |
| inletConcentration | Inlet Concentration | Required. Finite number; strictly above 0. |
| outletFlow | Outlet Flow | Required. Finite number; minimum 0. |
| outletConcentration | Outlet Concentration | Required. Finite number; minimum 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| inletMassRate | Inlet Mass Rate | Required. Finite number. |
| outletMassRate | Outlet Mass Rate | Required. Finite number. |
| removedMassRate | Removed Mass Rate | Required. Finite number. |
| efficiency | Efficiency | Required. Finite number. |
{
"input": {
"inletFlow": 100,
"inletConcentration": 2,
"outletFlow": 90,
"outletConcentration": 0.2
},
"output": {
"inletMassRate": 200,
"outletMassRate": 18,
"removedMassRate": 182,
"efficiency": 0.91
}
} Limitations and assumptions
- Use matching volumetric flow and concentration bases at inlet and outlet. Efficiency can be negative and is not clamped; the tool does not correct gas conditions, quantify uncertainty or prove dust-control adequacy.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Integrate changing measurements over time and reconcile storage and reactions when a constant-condition product is insufficient.
References
Similar or alternative tools
- Effluent Load Reference Ratio
Return load = concentration*flow and ratio = load/referenceLoad.
- Sludge Dewatering Polymer Dry Mass Basis Tool
Calculate sludge dewatering polymer dry mass basis from explicit caller-supplied inputs.