Hardy Cross Pipe Flow Calculator
Exactly one oriented single-loop Hardy Cross iteration, not shared-pipe network convergence or automatic balanced boundary flows. Caller independently establishes units, regime, calibration and applicability; this does not establish design-code compliance, authenticity, operational safety, treatment efficacy or a validated forecast.
Description
Hardy Cross adjusts an assumed pipe-loop flow distribution using head-loss imbalance.
Hardy Cross adjusts an assumed pipe-loop flow distribution using head-loss imbalance.1
One correction is a numerical step rather than a converged multi-loop network solution. Use this tool to calculate hardy Cross Pipe Flow from the supplied measurements and assumptions.
When to use Hardy Cross Pipe Flow Calculator
Use this tool to calculate hardy Cross Pipe Flow from the supplied measurements and assumptions. Establish the SI units or caller unit basis, load signs, measurement interval, model conditions and independently chosen coefficients or references.
How to use Hardy Cross Pipe Flow Calculator and understand its results
- Establish the SI units or caller unit basis, load signs, measurement interval, model conditions and independently chosen coefficients or references.
- Enter signedLoopFlowsM3Second, callerLoopResistance, callerHeadLossExponents, using the field meanings and rules below, then run the tool.
- Read oneHardyCrossCorrectionM3Second, correctedSingleLoopFlowsM3Second. Interpret the fields using their units, signs and evidence conventions below.
- If input validation fails, correct the reported field and run again. Before applying the result, check reference scope, model assumptions and any missing evidence or placeholder values.
| Input field | Meaning | Value type | Requirement |
|---|---|---|---|
| signedLoopFlowsM3Second | Signed loop flows m3 second | list of number | Required |
| callerLoopResistance | Caller loop resistance | list of number | Required |
| callerHeadLossExponents | Caller head loss exponents | list of number | Required |
Enter nonempty aligned finite signed loop flows, positive resistance coefficients and exponents from 1 through 3. Sum r×sign(q)×abs(q)^n and derivative r×n×abs(q)^(n−1), requiring positive derivative. Correction is minus head sum/derivative and is added to every signed loop flow. Only one loop step is performed; no network continuity repair or convergence iteration is provided.
deltaQ=−Σr_i×sign(q_i)×abs(q_i)^n_i / Σr_i×n_i×abs(q_i)^(n_i−1); corrected_i=q_i+deltaQ Use the exact units, boundary rules, ordering and missing-evidence conventions above.
| Output field | Meaning | Value type |
|---|---|---|
| oneHardyCrossCorrectionM3Second | One Hardy Cross Correction M3 Second; follow the units, sign, ordering and evidence convention stated above | number |
| correctedSingleLoopFlowsM3Second | Corrected Single Loop Flows M3 Second; follow the units, sign, ordering and evidence convention stated above | list of number |
{
"input": {
"signedLoopFlowsM3Second": [
2,
-1
],
"callerLoopResistance": [
1,
1
],
"callerHeadLossExponents": [
2,
2
]
},
"output": {
"oneHardyCrossCorrectionM3Second": -0.5,
"correctedSingleLoopFlowsM3Second": [
1.5,
-1.5
]
}
} Limitations and assumptions
One correction is a numerical step rather than a converged multi-loop network solution. Interpretation depends on the units, sampling scope and exact model described above.
All listed fields require explicit values. Unexpected fields, incorrect types, nonfinite numbers and sparse evidence arrays fail validation; the specific bounds and alignment requirements are stated above. Extremely large inputs or outputs can also be rejected. An input error is distinct from a successful result reporting false, no matches or missing evidence.
Alternative or Complementary methods
Use Seepage Flow Net Calculator for this related task: A flow-net seepage estimate uses the ratio of independently counted channels and potential drops.
Use Sewer Self-Cleansing Velocity Calculator when its separate inputs and assumptions fit the question: A wall-shear relation connects a target shear stress with a Darcy friction factor and flow velocity.
References
-
Hardy Cross Pipe Flow Calculator — tool.io
Similar or alternative tools
- Seepage Flow Net Calculator
A flow-net seepage estimate uses the ratio of independently counted channels and potential drops.
- Sewer Self-Cleansing Velocity Calculator
A wall-shear relation connects a target shear stress with a Darcy friction factor and flow velocity.