Skip to content

Main content

Canal Outline Support Share Tool

Calculate canal outline support share from explicit caller-supplied inputs.

Loading tool…

Description

Calculate scale-supported outlined length relative to the supplied canal outline.

A measured image outline may contain portions without a verified scale or sufficient evidence. Length-weighted support within the outlined portion differs from overall image completeness and from anatomical certainty.

Calculate scale-supported outlined length relative to the supplied canal outline.

When to use this tool

Use Canal Outline Support Share when summarizing support within supplied outlined segment lengths.

How to use the tool and how it works

  1. Enter segmentLengths, outlinePresent, scaleVerified. Keep parallel arrays aligned. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read outlineLength, supportedLength, share, defined. Inspect defined before interpreting the associated values.

Require equally long segmentLengths, outlinePresent and scaleVerified arrays and nonnegative lengths. outlineLength sums outline-present segments; supportedLength additionally requires scaleVerified. share = supportedLength/outlineLength when positive, otherwise zero with defined = false.1

Input fieldMeaning and unitsAccepted input
segmentLengthsSegment LengthsRequired. Array of finite number; minimum 0; maximum items 256.
outlinePresentOutline PresentRequired. Array of boolean; maximum items 256.
scaleVerifiedScale VerifiedRequired. Array of boolean; maximum items 256.
Output fieldInterpretationReturned shape
outlineLengthOutline LengthRequired. Finite number.
supportedLengthSupported LengthRequired. Finite number.
shareDimensionless selected contribution divided by the stated total; not percent.Required. Finite number.
definedWhether the stated denominator has positive support; read this before interpreting a zero placeholder.Required. Boolean.
json
{
  "input": {
    "segmentLengths": [
      2,
      3,
      5
    ],
    "outlinePresent": [
      true,
      true,
      false
    ],
    "scaleVerified": [
      true,
      false,
      true
    ]
  },
  "output": {
    "outlineLength": 5,
    "supportedLength": 2,
    "share": 0.4,
    "defined": true
  }
}

Limitations and assumptions

  • This measures support within supplied outlined length, not all anatomical length. Flags, segment overlap and calibration are not independently validated.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Review the image, calibration and segmentation method before drawing anatomical or clinical conclusions.

References

  1. Calculation and input contract: endodontics/canal-outline-support-share — tool.io

Similar or alternative tools