Calculate nominal duration of one constant-rate potential sweep.
Electrochemical quantities require explicit electrode references, current sign, area definition and time basis. Geometric area differs from active-area conventions, charge differs from charge equivalents, and a logarithmic current coordinate needs a same-unit reference magnitude. Local sign changes and coordinate terms do not fit kinetics or establish a valid experiment.
Calculate nominal duration of one constant-rate potential sweep.
When to use this tool
Use CV Potential Sweep Time when you already have startPotentialVolts, endPotentialVolts, scanRateVoltsPerSecond and need to calculate nominal duration of one constant-rate potential sweep.
How to use the tool and how it works
- Enter startPotentialVolts, endPotentialVolts, scanRateVoltsPerSecond. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read sweepSeconds. Use the output convention below.
Require scanRateVoltsPerSecond>0; return abs(endPotentialVolts-startPotentialVolts)/scanRateVoltsPerSecond.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| startPotentialVolts | Start Potential Volts | Required. Finite number. |
| endPotentialVolts | End Potential Volts | Required. Finite number. |
| scanRateVoltsPerSecond | Positive constant rate magnitude for one linear sweep; no hold or return time. | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| sweepSeconds | Sweep Seconds | Required. Finite number. |
{
"input": {
"startPotentialVolts": -0.2,
"endPotentialVolts": 0.8,
"scanRateVoltsPerSecond": 0.1
},
"output": {
"sweepSeconds": 10
}
} Limitations and assumptions
- Equal potentials give zero. This is one sweep without holds or return legs; no scan waveform, current response or suitable rate is determined.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Inspect calibrated instrument records, reference-electrode details, area definitions and the complete experiment before interpreting results. Use the full electrochemical model and verified operating conditions when a local current, charge, sweep or impedance-representation term cannot answer the scientific question.