Residual Current Three Conductor Vector Term Tool

Sum three supplied RMS conductor-current phasors algebraically without a protection or safety verdict.

Loading tool…

Description

Sum each component and return residualReal, residualImaginary and their hypotenuse magnitude.

Sinusoidal electrical calculations need a common frequency, phase reference and RMS or peak convention. Phasor sums, complex power and composite RMS describe different operations; a sign label alone does not establish a physical connection or waveform.

Sum each component and return residualReal, residualImaginary and their hypotenuse magnitude.

When to use this tool

Use Residual Current Three Conductor Vector Term when checking a stated phasor, power or RMS convention.

How to use the tool and how it works

  1. Enter real, imaginary. Keep parallel arrays aligned. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read residualReal, residualImaginary, magnitude. Use the output convention below.

Require exactly three real and three imaginary current components. Sum each component and return residualReal, residualImaginary and their hypotenuse magnitude.1

Input fieldMeaning and unitsAccepted input
realRealRequired. Array of finite number; maximum items 256.
imaginaryImaginaryRequired. Array of finite number; maximum items 256.
Output fieldInterpretationReturned shape
residualRealResidual RealRequired. Finite number.
residualImaginaryResidual ImaginaryRequired. Finite number.
magnitudeMagnitudeRequired. Finite number.
json
{
  "input": {
    "real": [
      1,
      -1,
      0
    ],
    "imaginary": [
      0,
      0,
      0
    ]
  },
  "output": {
    "residualReal": 0,
    "residualImaginary": 0,
    "magnitude": 0
  }
}

Limitations and assumptions

  • All phasors must share frequency, reference phase and RMS or peak convention. This vector residual does not validate a protective device or establish safe leakage current.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use compatible measured waveforms and a complete circuit or harmonic model when signals are distorted, references differ or practical limits matter.

References

  1. Calculation and input contract: electricity/residual-current-three-conductor-vector-term — tool.io