Inductor Energy Current Sign Invariance Tool

Compare ideal inductor stored energy before and after reversing current polarity.

Loading tool…

Description

energy = 0.5*inductance*current² and reversedEnergy returns the same value.

Capacitors and inductors store energy under voltage and current conventions, respectively. An ideal endpoint energy difference, charge balance or flux-linkage balance does not determine the transient path or how energy is dissipated.

energy = 0.5*inductance*current² and reversedEnergy returns the same value.

When to use this tool

Use Inductor Energy Current Sign Invariance when checking one ideal storage-state comparison or supplied balance.

How to use the tool and how it works

  1. Enter inductance, current. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read energy, reversedEnergy. Use the output convention below.

Require nonnegative inductance. energy = 0.5*inductance*current² and reversedEnergy returns the same value.1

Input fieldMeaning and unitsAccepted input
inductanceInductance; use henries with SI electrical inputs.Required. Finite number; minimum 0.
currentSigned electric current; use amperes with SI electrical inputs.Required. Finite number.
Output fieldInterpretationReturned shape
energyEnergyRequired. Finite number.
reversedEnergyReversed EnergyRequired. Finite number.
json
{
  "input": {
    "inductance": 2,
    "current": -3
  },
  "output": {
    "energy": 9,
    "reversedEnergy": 9
  }
}

Limitations and assumptions

  • Use H and A for joules. Sign invariance applies to an ideal linear uncoupled inductor; mutual energy and nonlinear hysteretic behavior require other models.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use a complete switching and loss model, with component limits, when analyzing practical connections or energy transfer.

References

  1. Calculation and input contract: electricity/inductor-energy-current-sign-invariance — tool.io