Skip to content

Main content

Capacitor Charge Residual Tool

Compare supplied signed charge against C times measured voltage in compatible units; no charging transient model.

Loading tool…

Description

expectedCharge = capacitance*measuredVoltage; residual = measuredCharge-expectedCharge.

Capacitors and inductors store energy under voltage and current conventions, respectively. An ideal endpoint energy difference, charge balance or flux-linkage balance does not determine the transient path or how energy is dissipated.

expectedCharge = capacitance*measuredVoltage; residual = measuredCharge-expectedCharge.

When to use this tool

Use Capacitor Charge Residual when checking one ideal storage-state comparison or supplied balance.

How to use the tool and how it works

  1. Enter measuredCharge, capacitance, measuredVoltage. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read expectedCharge, residual. Use the output convention below.

Require nonnegative capacitance. expectedCharge = capacitance*measuredVoltage; residual = measuredCharge-expectedCharge.1

Input fieldMeaning and unitsAccepted input
measuredChargeMeasured ChargeRequired. Finite number.
capacitanceCapacitance; use farads with SI electrical inputs.Required. Finite number; minimum 0.
measuredVoltageMeasured VoltageRequired. Finite number.
Output fieldInterpretationReturned shape
expectedChargeExpected ChargeRequired. Finite number.
residualResidualRequired. Finite number.
json
{
  "input": {
    "measuredCharge": 12,
    "capacitance": 2,
    "measuredVoltage": 5
  },
  "output": {
    "expectedCharge": 10,
    "residual": 2
  }
}

Limitations and assumptions

  • Use F, V and C. The constant-capacitance model does not fit a capacitance, quantify uncertainty or establish that a measured device is ideal.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use a complete switching and loss model, with component limits, when analyzing practical connections or energy transfer.

References

  1. Calculation and input contract: electricity/capacitor-charge-residual — tool.io

Similar or alternative tools