Description
Classify an actuator input against a supplied deadzone interval.
Control boundaries and stability terms depend on state history, sign conventions and the full system dynamics. A finite scalar factor, one pole or one frequency sample is not sufficient to establish safe closed-loop behavior.
Classify an actuator input against a supplied deadzone interval.
When to use this tool
Use Actuator Dead Zone Edge Token when checking a supplied saturation, hysteresis or local stability condition.
How to use the tool and how it works
- Enter input, lower, upper, includeEdges. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read inDeadZone, side. Inspect inDeadZone before interpreting the associated values.
Classify an actuator input against a supplied deadzone interval. Require upper >= lower; includeEdges controls endpoint membership; outside returns lower when input <= lower, otherwise upper.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| input | Input | Required. Finite number. |
| lower | Lower | Required. Finite number. |
| upper | Upper | Required. Finite number. |
| includeEdges | Include Edges | Required. Boolean. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| inDeadZone | In Dead Zone | Required. Boolean. |
| side | inside, lower or upper under the edge convention; coincident open boundaries select lower. | Required. Text; maximum UTF-16 length 8192. |
{
"input": {
"input": 1,
"lower": -1,
"upper": 1,
"includeEdges": true
},
"output": {
"inDeadZone": true,
"side": "inside"
}
} Limitations and assumptions
- For a degenerate open interval, the sole endpoint is labeled lower; no physical deadzone is estimated.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Analyze the complete dynamic system and practical constraints before interpreting a local result as robust or safe operation.
References
Similar or alternative tools
- Actuator Rate Limit One Step Gap
Rate-limit one actuator-command step with asymmetric rise/fall bounds.
- Control Saturation Duty Fraction Term
Return a saturated command and its range fraction.