Skip to content

Main content

Simulation Time Unit Crosswalk

Place a simulation time on an explicit physical-seconds scale and origin without inferring a model’s characteristic time.

Loading tool…

Description

Map supplied simulation time to a physical-seconds reference.

Numerical physics calculations depend on discretization, index conventions, boundary conditions and model units. A local force kick is only part of an integration method, a stencil residual is not a solved field, and a one-sided power weight is not a spectral-density normalization. Floating-point resolution also limits grid and coordinate representations.

Map supplied simulation time to a physical-seconds reference.

When to use this tool

Use Simulation Time Unit Crosswalk when you already have simulationTime, physicalSecondsPerTimeUnit, originPhysicalSeconds and need to map supplied simulation time to a physical-seconds reference.

How to use the tool and how it works

  1. Enter simulationTime, physicalSecondsPerTimeUnit, originPhysicalSeconds. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read physicalTimeSeconds. Use the output convention below.

Require physicalSecondsPerTimeUnit>0; return originPhysicalSeconds+simulationTime*factor.1

Input fieldMeaning and unitsAccepted input
simulationTimeSimulation TimeRequired. Finite number.
physicalSecondsPerTimeUnitPhysical Seconds Per Time UnitRequired. Finite number; strictly above 0.
originPhysicalSecondsOrigin Physical SecondsRequired. Finite number.
Output fieldInterpretationReturned shape
physicalTimeSecondsPhysical Time SecondsRequired. Finite number.
json
{
  "input": {
    "simulationTime": 12,
    "physicalSecondsPerTimeUnit": 0.5,
    "originPhysicalSeconds": 100
  },
  "output": {
    "physicalTimeSeconds": 106
  }
}

Limitations and assumptions

  • Signed simulation time is accepted. No calibration, simulation epoch, clock, physical validity or actual time evolution is inferred.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use the complete discretized model, integration algorithm and boundary treatment. Assess convergence, conservation and stability with the full calculation; individual residuals, CFL components, relaxation terms and index mappings do not establish numerical accuracy or physical validity.

References

  1. Calculation and input contract: computational-physics/simulation-time-unit-crosswalk — tool.io

Similar or alternative tools