Thermohydrogram Ratio Classifier
Explicit caller thermohydrogram Pvspositive Tax is ratio and month dryness screen—not Lang annual factor or biological water balance. Caller independently establishes homogeneous observation coverage and model/reference applicability; not observed future climate, crop suitability or validated drought severity.
Description
A thermohydrogram compares precipitation with a scaled temperature-related reference.
A thermohydrogram compares precipitation with a scaled temperature-related reference.1
The scale factor is an independently chosen convention, not an automatic drought calibration. Use Thermohydrogram Ratio Classifier to evaluate the supplied inputs under the model explained below.
When to use Thermohydrogram Ratio Classifier
Use Thermohydrogram Ratio Classifier to evaluate the supplied inputs under the model explained below. Establish the units, measurement scope and model assumptions before entering values.
How to use Thermohydrogram Ratio Classifier and understand its results
- Establish the units, measurement scope and model assumptions before entering values.
- Enter Monthly temperature c, Monthly precipitation mm, Caller precipitation mm per temperature c using the field table and validation rules below, then run the tool.
- Read Monthly signed thermohydrogram reserves mm, Observed dry month count; interpret the units, signs, ordering and unknown-value placeholders described below.
- Correct reported input errors and rerun. Apply successful results according to their specific meanings and check the assumptions before using them in a decision.
| Input field | Meaning | Value type | Requirement |
|---|---|---|---|
| monthlyTemperatureC | Monthly temperature c | array of number | Required; constraints below |
| monthlyPrecipitationMm | Monthly precipitation mm | array of number | Required; constraints below |
| callerPrecipitationMmPerTemperatureC | Caller precipitation mm per temperature c | number | Required; constraints below |
Enter twelve January–December finite temperature values in °C and nonnegative precipitation values in mm, plus a positive caller precipitation-per-temperature factor in mm/°C. Compute precipitation minus factor×max(0,temperature) for each month and count strictly negative reserves. Zero reserve is not dry in this check. No factor, climate period or calibrated drought rule is selected.
reserveMm[i]=precipMm[i]−factor×max(0,tempC[i]); dryMonths=count(reserve<0) Use the field order, units and branch conditions described above.
| Output field | Meaning | Value type |
|---|---|---|
| monthlySignedThermohydrogramReservesMm | Monthly signed thermohydrogram reserves mm | array of number |
| observedDryMonthCount | Observed dry month count | number |
{
"input": {
"monthlyTemperatureC": [
20,
20,
20,
20,
20,
20,
20,
20,
20,
20,
20,
20
],
"monthlyPrecipitationMm": [
20,
20,
20,
20,
20,
20,
20,
20,
20,
20,
20,
20
],
"callerPrecipitationMmPerTemperatureC": 2
},
"output": {
"monthlySignedThermohydrogramReservesMm": [
-20,
-20,
-20,
-20,
-20,
-20,
-20,
-20,
-20,
-20,
-20,
-20
],
"observedDryMonthCount": 12
}
} Limitations and assumptions
The scale factor is an independently chosen convention, not an automatic drought calibration. Apply the exact scope and assumptions explained above.
All listed fields require explicit values. Unexpected fields, incorrect types, nonfinite numbers and sparse arrays fail validation. Domain-specific bounds, alignments and supported tokens are explained above; extremely large inputs or outputs can also be rejected. Input errors differ from successful false results, empty match lists and unknown-evidence placeholders.
Alternative or Complementary methods
Use Lang Rain Factor Calculator for a related task: Lang's rain factor divides annual precipitation by a positive mean temperature.
Use Firbas Humidity Factor Calculator for a related task: A named humidity factor requires an identified method and reference convention.
References
-
Thermohydrogram Ratio Classifier — tool.io
Similar or alternative tools
- Lang Rain Factor Calculator
Lang's rain factor divides annual precipitation by a positive mean temperature.
- Firbas Humidity Factor Calculator
A named humidity factor requires an identified method and reference convention.