Chill Hours Accumulator 0-7.2C

Declaredinclusive0…7.2Cchill-hourbinaccumulationactualuniformtimeobservations,not DynamicModelchillportionsor dormancyforecast. Actual independent units,calibration,measurement definitions/coverage and model applicability;not a climate forecast,causal determination,geodesy operation or safe travel/design approval.

Description

A simple chill-hour model totals time spent in a declared cool-temperature interval.

A simple chill-hour model totals time spent in a declared cool-temperature interval.1

This tool counts uniform observation windows with temperatures from 0 through 7.2 °C inclusive, rather than calculating chill portions or selecting a crop requirement.

When to use Chill Hours Accumulator 0-7.2C

Use this tool to apply the stated chill hours accumulator 0-7.2c operation with an explicit input and unit basis.

How to use Chill Hours Accumulator 0-7.2C and how it works

  1. Establish the measurement basis and units described above.
  2. Enter actualEqualObservationTemperaturesC, actualObservationHoursEach and run the tool.
  3. Read result.value using the output meanings below.
  4. If input is rejected, correct the stated type, range, ordering or alignment issue and rerun; review successful results under the declared convention.
Input fieldMeaningValue typeRequirement
actualEqualObservationTemperaturesCEqual Observation Temperatures C. Units, ordering and applicable branch are specified in the algorithm.array of numberrequired; dense; align related rows as specified; further conditions in the algorithm
actualObservationHoursEachObservation Hours Each. Units, ordering and applicable branch are specified in the algorithm.numberrequired; finite; strictly positive; further conditions in the algorithm

Require nonempty finite temperatures and positive duration hours for every observation. Count the temperatures in the closed interval [0,7.2] and multiply by that duration; unequal windows need preprocessing.

chillHours = count(0 ≤ temperatureC ≤ 7.2) × hoursEach

Apply the declared units, ordering and branch conditions.

Output fieldMeaningValue type
resultObject containing the declared output fields.object
result.valueTotal qualifying chill hours.number
json
{
  "input": {
    "actualEqualObservationTemperaturesC": [
      -1,
      0,
      7.2,
      8
    ],
    "actualObservationHoursEach": 2
  },
  "output": {
    "result": {
      "value": 4
    }
  }
}

Limitations and assumptions

The output applies the declared operation to the values you supply. Establish the measurement basis, units, coefficients and any caller-selected rules before interpreting it. The tool does not independently collect or verify observations or decide whether a model or reference applies.

Supply explicit required fields with the documented types and dense aligned arrays. Unknown fields, wrong types and nonfinite numbers are rejected. Branch-specific constraints are explained above. A returned boolean, signed difference or tied result follows the stated convention; an input error instead means the required input contract was not satisfied. Very large inputs or outputs may be rejected by shared resource limits.

Alternative or Complementary methods

For a related operation, use Thawing Index Accumulator Calculator. A thawing index accumulates warmth above freezing using daily mean temperature.

For a related operation, use Accumulated Freezing Degree Days Calculator. Freezing degree-days accumulate the magnitude of daily mean temperatures below freezing.

References

  1. Chill Hours Accumulator 0-7.2C — tool.io

Similar or alternative tools

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies