Skip to content

Main content

Solid Liquid Moisture Basis Term Tool

Calculate solid liquid moisture basis term from explicit caller-supplied inputs.

Loading tool…

Description

Convert dry-basis concentration to wet-basis amount.

A process stream can be described on mass, mole, phase or solvent bases, which are not interchangeable. Lever rules, partition factors and operating-line terms assume compatible composition definitions and an appropriate physical model; a local balance does not determine equilibrium properties or a complete separation design.

Convert dry-basis concentration to wet-basis amount.

When to use this tool

Use Solid Liquid Moisture Basis Term when checking the stated stream composition, phase or separation-model term.

How to use the tool and how it works

  1. Enter wetMass, waterFraction, dryBasisConcentration. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read dryMass, constituentMass, wetBasisConcentration. Use the output convention below.

Convert dry-basis concentration to wet-basis amount. Require wetMass/dryBasisConcentration >= 0 and waterFraction in [0,1); dryMass = wet*(1-water), constituentMass = dryMass*dry concentration, wetBasisConcentration = (1-water)*dry concentration.1

Input fieldMeaning and unitsAccepted input
wetMassWet MassRequired. Finite number; minimum 0.
waterFractionWater mass fraction of wet material, strictly below one. Unit: 1.Required. Finite number; minimum 0; strictly below 1.
dryBasisConcentrationConstituent mass per dry solid mass, in compatible mass units.Required. Finite number; minimum 0.
Output fieldInterpretationReturned shape
dryMassDry MassRequired. Finite number.
constituentMassConstituent MassRequired. Finite number.
wetBasisConcentrationWet Basis ConcentrationRequired. Finite number.
json
{
  "input": {
    "wetMass": 100,
    "waterFraction": 0.2,
    "dryBasisConcentration": 0.1
  },
  "output": {
    "dryMass": 80,
    "constituentMass": 8,
    "wetBasisConcentration": 0.08000000000000002
  }
}

Limitations and assumptions

  • Water fraction is wet-mass based; concentrations must be amount per compatible mass and no moisture measurement occurs.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified equilibrium and material-property data on consistent bases and solve the complete process model for actual separation or equipment decisions.

References

  1. Calculation and input contract: chemical-engineering/solid-liquid-moisture-basis-term — tool.io

Similar or alternative tools