Hopper Cone Holdup Volume Term Tool

Conical-frustum geometric inventory; flow pattern, bridging and unfilled dead zones are excluded.

Loading tool…

Description

Return conical-frustum holdup volume and mass.

Physical process calculations combine supplied geometry, material properties and pressure or gas-state conventions. A density scaling, ideal-gas correction or vessel-volume term can be dimensionally consistent without verifying the actual fluid state, flow regime or equipment suitability.

Return conical-frustum holdup volume and mass.

When to use this tool

Use Hopper Cone Holdup Volume Term when evaluating the stated geometric, fluid-property or gas-state term.

How to use the tool and how it works

  1. Enter topRadius, outletRadius, height, bulkDensity. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read volume, mass. Use the output convention below.

Return conical-frustum holdup volume and mass. Require topRadius >= outletRadius >= 0 and height/bulkDensity >= 0; volume = pi*h*(R²+R*r+r²)/3, mass = volume*density.1

Input fieldMeaning and unitsAccepted input
topRadiusTop RadiusRequired. Finite number.
outletRadiusOutlet RadiusRequired. Finite number; minimum 0.
heightHeightRequired. Finite number; minimum 0.
bulkDensityBulk DensityRequired. Finite number; minimum 0.
Output fieldInterpretationReturned shape
volumeConical-frustum volume in cubed input length units; mass uses compatible bulkDensity.Required. Finite number.
massMassRequired. Finite number.
json
{
  "input": {
    "topRadius": 2,
    "outletRadius": 1,
    "height": 3,
    "bulkDensity": 2
  },
  "output": {
    "volume": 21.991148575128552,
    "mass": 43.982297150257104
  }
}

Limitations and assumptions

  • Use one length unit and matching bulk mass/volume density; actual fill shape, flow and hopper discharge are not modeled.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified geometry and state-specific material data with an appropriate full engineering model for actual flow, storage or equipment design.

References

  1. Calculation and input contract: chemical-engineering/hopper-cone-holdup-volume-term — tool.io