Membrane Capacitance Area Thickness Factor Tool

Ideal uniform parallel-plate membrane in SI units, excluding fringing and frequency dispersion.

Loading tool…

Description

Return parallel-plate membrane capacitance.

Membrane electrical quantities distinguish total from area-specific properties, concentration ratios from activities and single-ion from multi-ion models. Local capacitance, current or potential terms require compatible sign, valence, temperature and unit conventions without themselves validating a biological membrane.

Return parallel-plate membrane capacitance.

When to use this tool

Use Membrane Capacitance Area Thickness Factor when evaluating the stated membrane, ionic or area-basis term.

How to use the tool and how it works

  1. Enter relativePermittivity, vacuumPermittivity, area, thickness. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read capacitance, capacitancePerArea. Use the output convention below.

Return parallel-plate membrane capacitance. Require positive relative/vacuum permittivity and thickness, area >= 0; capacitancePerArea = epsilonRelative*epsilonVacuum/thickness, capacitance multiplies area.1

Input fieldMeaning and unitsAccepted input
relativePermittivityPositive dimensionless relative permittivity.Required. Finite number; strictly above 0.
vacuumPermittivitySupplied vacuum permittivity, F/m for SI capacitance.Required. Finite number; strictly above 0.
areaAreaRequired. Finite number; minimum 0.
thicknessThicknessRequired. Finite number; strictly above 0.
Output fieldInterpretationReturned shape
capacitanceCapacitanceRequired. Finite number.
capacitancePerAreaCapacitance Per AreaRequired. Finite number.
json
{
  "input": {
    "relativePermittivity": 2,
    "vacuumPermittivity": 8.85e-12,
    "area": 0.01,
    "thickness": 0.000001
  },
  "output": {
    "capacitance": 1.77e-7,
    "capacitancePerArea": 0.000017700000000000003
  }
}

Limitations and assumptions

  • Compatible SI inputs produce farads; the uniform dielectric geometry omits interfaces, frequency response and membrane complexity.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified concentrations, activities, geometry and electrical calibration with the appropriate complete membrane/channel model for physiological interpretation.

References

  1. Calculation and input contract: biophysics/membrane-capacitance-area-thickness-factor — tool.io

Similar or alternative tools