Skip to content

Main content

Diffusion Time Scale Ratio Tool

Compare L²/D scales under the same geometry convention, without a diffusion model fit.

Loading tool…

Description

Return a ratio of diffusive time scales.

Diffusive and thermal scales depend on dimensionality, geometry, drag and compatible energy/time units. A local displacement correction or ideal spherical diffusivity is distinct from fitting a stochastic trajectory or establishing that a measured system satisfies the model.

Return a ratio of diffusive time scales.

When to use this tool

Use Diffusion Time Scale Ratio when checking the stated diffusion, drift, work or thermal-energy convention.

How to use the tool and how it works

  1. Enter firstLength, firstDiffusivity, secondLength, secondDiffusivity. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read timeScaleRatio. Use the output convention below.

Return a ratio of diffusive time scales. Require firstLength >= 0 and secondLength/both diffusivities > 0; timeScaleRatio = (firstLength/secondLength)²*secondDiffusivity/firstDiffusivity.1

Input fieldMeaning and unitsAccepted input
firstLengthFirst LengthRequired. Finite number; minimum 0.
firstDiffusivityFirst DiffusivityRequired. Finite number; strictly above 0.
secondLengthSecond LengthRequired. Finite number; strictly above 0.
secondDiffusivitySecond DiffusivityRequired. Finite number; strictly above 0.
Output fieldInterpretationReturned shape
timeScaleRatioTime Scale RatioRequired. Finite number.
json
{
  "input": {
    "firstLength": 2,
    "firstDiffusivity": 1,
    "secondLength": 1,
    "secondDiffusivity": 2
  },
  "output": {
    "timeScaleRatio": 8
  }
}

Limitations and assumptions

  • The same length-squared/diffusivity convention is assumed for both systems; no geometry-specific first-passage time is solved.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use calibrated trajectories and an appropriate geometry/noise/transport model for fitted diffusion parameters, uncertainty or molecular mechanisms.

References

  1. Calculation and input contract: biophysics/diffusion-time-scale-ratio — tool.io

Similar or alternative tools