Skip to content

Main content

Channel Open Closed Dwell Pair

Combine explicit open and closed channel dwell durations for one positive cycle and its open fraction.

Loading tool…

Description

Calculate supplied open/closed dwell cycle duration and open fraction.

Biophysical scalar models require explicit signal, concentration, temperature, energy and geometric conventions. Effective concentration differs from dimensionless activity, a single displacement differs from mean-square displacement, and a fluorescence yield ratio needs absorption and refractive-index corrections. Supplied model parameters do not establish that the model applies to an experiment.

Calculate supplied open/closed dwell cycle duration and open fraction.

When to use this tool

Use Channel Open Closed Dwell Pair when you already have openDwell, closedDwell and need to calculate supplied open/closed dwell cycle duration and open fraction.

How to use the tool and how it works

  1. Enter openDwell, closedDwell. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read cycleDuration, openFraction. Use the output convention below.

Require both durations>=0 with positive sum; return sum and open/sum.1

Input fieldMeaning and unitsAccepted input
openDwellOpen DwellRequired. Finite number; minimum 0.
closedDwellClosed DwellRequired. Finite number; minimum 0.
Output fieldInterpretationReturned shape
cycleDurationopenDwell+closedDwell, required positive and finite.Required. Finite number.
openFractionOpen FractionRequired. Finite number.
json
{
  "input": {
    "openDwell": 3,
    "closedDwell": 9
  },
  "output": {
    "cycleDuration": 12,
    "openFraction": 0.25
  }
}

Limitations and assumptions

  • Matching time bases are assumed. No channel, event, kinetics, stationary open probability or actual dwell time is inferred.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use the complete physical model, calibrated measurements and uncertainty analysis. Check reference states, photon-signal bases, diffusion assumptions and binding-constant conventions before interpreting local contributions as physical measurements.

References

  1. Calculation and input contract: biophysics/channel-open-closed-dwell-pair — tool.io

Similar or alternative tools