Muscle Moment Arm Torque Factor Tool

Single force projected along the tendon with a signed supplied moment arm; no muscle-recruitment or clinical inference.

Loading tool…

Description

Return projected tendon force and signed moment-arm torque.

Mechanical inertia, torque and muscle-force projections require compatible axes, origins and geometric assumptions. A parallel-axis contribution, planar moment or ideal pennation factor is one local model term rather than a full anatomical load or muscle-activation calculation.

Return projected tendon force and signed moment-arm torque.

When to use this tool

Use Muscle Moment Arm Torque Factor when evaluating the stated segment, moment, inertia or ideal muscle-geometry term.

How to use the tool and how it works

  1. Enter force, momentArm, pennationRadians. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read tendonForce, torque. Use the output convention below.

Return projected tendon force and signed moment-arm torque. Require force >= 0 and pennation in [0,pi/2]; tendonForce = force*cos(angle), torque = tendonForce*momentArm.1

Input fieldMeaning and unitsAccepted input
forceForceRequired. Finite number; minimum 0.
momentArmMoment ArmRequired. Finite number.
pennationRadiansPennation Radians Unit: rad.Required. Finite number; minimum 0.
Output fieldInterpretationReturned shape
tendonForceTendon ForceRequired. Finite number.
torqueTorqueRequired. Finite number.
json
{
  "input": {
    "force": 100,
    "momentArm": 0.05,
    "pennationRadians": 0
  },
  "output": {
    "tendonForce": 100,
    "torque": 5
  }
}

Limitations and assumptions

  • The signed arm and geometry are supplied; no muscle recruitment, actual joint load or injury risk is determined.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified anatomy and calibration, a consistent coordinate frame and a complete appropriate mechanical model for actual loading or clinical interpretation.

References

  1. Calculation and input contract: biomechanics/muscle-moment-arm-torque-factor — tool.io