Motion Marker Rigid Segment Length Residual

Compare Euclidean distance between supplied aligned marker coordinates with an explicit rigid-segment reference length.

Loading tool…

Description

Compare supplied marker-pair distance with a reference segment length.

Movement geometry depends on coordinate registration, time origins, force signs and reference axes. A moment arm must already represent perpendicular leverage, a stride percentage has an endpoint convention, and a toe-to-heel projection differs from full Euclidean separation. Scalar results do not establish a movement diagnosis or a safe activity.

Compare supplied marker-pair distance with a reference segment length.

When to use this tool

Use Motion Marker Rigid Segment Length Residual when you already have firstMarker, secondMarker, referenceLength and need to compare supplied marker-pair distance with a reference segment length.

How to use the tool and how it works

  1. Enter firstMarker, secondMarker, referenceLength. Follow any array-alignment requirements below. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read measuredLength, lengthResidual. Use the output convention below.

Require equal-length nonempty coordinate arrays and referenceLength>=0; calculate Euclidean distance with Math.hypot of differences and subtract referenceLength.1

Input fieldMeaning and unitsAccepted input
firstMarkerNonempty coordinate vector aligned in dimension, frame and units with secondMarker; not restricted to three dimensions.Required. Array of finite number; maximum items 256.
secondMarkerSecond MarkerRequired. Array of finite number; maximum items 256.
referenceLengthReference LengthRequired. Finite number; minimum 0.
Output fieldInterpretationReturned shape
measuredLengthMeasured LengthRequired. Finite number.
lengthResidualLength ResidualRequired. Finite number.
json
{
  "input": {
    "firstMarker": [
      0,
      0,
      0
    ],
    "secondMarker": [
      3,
      4,
      0
    ],
    "referenceLength": 4
  },
  "output": {
    "measuredLength": 5,
    "lengthResidual": 1
  }
}

Limitations and assumptions

  • Dimension and units are caller-defined, not limited to 3D. No marker tracking, rigid-body validity, calibration, anatomical segment or clinical result is verified.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use calibrated motion, force and timing records with a complete biomechanical model. Check coordinate frames, axis normalization and sampling limitations before interpreting local distances, moments or phase values as performance or clinical findings.

References

  1. Calculation and input contract: biomechanics/motion-marker-rigid-segment-length-residual — tool.io