Skip to content

Main content

Scaffold Pore Strut Clearance Gap Tool

Calculate scaffold pore strut clearance gap from explicit caller-supplied inputs.

Loading tool…

Description

Return nominal and swelling-adjusted strut clearance.

Biofabrication bookkeeping separates nominal geometry, deposition, material bases, layer heights and verification assertions. A local surface, fill fraction or dimensional residual describes supplied values rather than demonstrating an actual construct’s shape, material quality or biological suitability.

Return nominal and swelling-adjusted strut clearance.

When to use this tool

Use Scaffold Pore Strut Clearance Gap when checking the stated benign build geometry, measurement, material or record convention.

How to use the tool and how it works

  1. Enter pitch, firstWidth, secondWidth, swellingFraction. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read nominalGap, swollenGap. Use the output convention below.

Return nominal and swelling-adjusted strut clearance. Require nonnegative pitch/widths and swellingFraction > -1; nominal gap = pitch-(w1+w2)/2, swollen gap multiplies both widths by 1+swelling.1

Input fieldMeaning and unitsAccepted input
pitchPitchRequired. Finite number; minimum 0.
firstWidthFirst WidthRequired. Finite number; minimum 0.
secondWidthSecond WidthRequired. Finite number; minimum 0.
swellingFractionSwelling Fraction Unit: 1.Required. Finite number; strictly above -1.
Output fieldInterpretationReturned shape
nominalGapNominal GapRequired. Finite number.
swollenGapSwollen GapRequired. Finite number.
json
{
  "input": {
    "pitch": 10,
    "firstWidth": 2,
    "secondWidth": 4,
    "swellingFraction": 0.1
  },
  "output": {
    "nominalGap": 7,
    "swollenGap": 6.699999999999999
  }
}

Limitations and assumptions

  • Negative gaps report overlap; swelling, actual pore geometry and biological or manufacturing suitability are not inferred.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified manufacturing records, measured geometry and an appropriate complete process/material assessment for actual construct quality, performance or safe use.

References

  1. Calculation and input contract: biofabrication/scaffold-pore-strut-clearance-gap — tool.io

Similar or alternative tools