Description
Return scaled marker gauge length and engineering strain.
Material and fixture mechanics depend on loading mode, geometry, reference state and constitutive assumptions. A secant modulus, Euler load or spring-energy term is a limited model contribution rather than validation of structural capacity, fatigue life or clinical device suitability.
Return scaled marker gauge length and engineering strain.
When to use this tool
Use Tissue Sample Gauge Length when evaluating the stated benign bench mechanical or timing term.
How to use the tool and how it works
- Enter markerOne, markerTwo, suppliedScale, referenceLength. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read gaugeLength, signedStrain. Use the output convention below.
Return scaled marker gauge length and engineering strain. Require suppliedScale/referenceLength > 0; gaugeLength = abs(markerTwo-markerOne)*scale, signedStrain = (gaugeLength-reference)/reference.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| markerOne | Marker One | Required. Finite number. |
| markerTwo | Marker Two | Required. Finite number. |
| suppliedScale | Supplied Scale | Required. Finite number; strictly above 0. |
| referenceLength | Reference Length | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| gaugeLength | Gauge Length | Required. Finite number. |
| signedStrain | Signed Strain | Required. Finite number. |
{
"input": {
"markerOne": 10,
"markerTwo": 30,
"suppliedScale": 0.5,
"referenceLength": 8
},
"output": {
"gaugeLength": 10,
"signedStrain": 0.25
}
} Limitations and assumptions
- Marker order is removed by absolute value; no tracking, 3D geometry, tissue properties or appropriate strain target is verified.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use verified material properties and an appropriate complete structural/test model with qualified engineering assessment for practical loading, lifetime or device decisions.
References
Similar or alternative tools
- Tissue Sample Strain Reference
Return tissue-sample engineering strain.
- Hydrogel Compression Modulus One Slope
Return a secant compression modulus.