Skip to content

Main content

Microfluidic Hydraulic Resistance One Channel Tool

Rectangular-channel laminar resistance using the 1-0.63*h/w first-order aspect correction; h<=w and consistent SI units.

Loading tool…

Description

Return approximate hydraulic resistance of one rectangular microchannel.

Biological engineering calculations combine supplied geometry, material properties, transport and quantity bases. An ideal channel resistance, scaffold fraction or thermal time scale can be dimensionally consistent without establishing real process conditions, safe exposure or biological performance.

Return approximate hydraulic resistance of one rectangular microchannel.

When to use this tool

Use Microfluidic Hydraulic Resistance One Channel when checking the stated benign geometry, transport, phantom or material-basis term.

How to use the tool and how it works

  1. Enter viscosity, length, width, height. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read resistance. Use the output convention below.

Return approximate hydraulic resistance of one rectangular microchannel. Require viscosity/length >= 0 and positive height <= width; resistance = 12*viscosity*length/[width*height³*(1-0.63*height/width)].1

Input fieldMeaning and unitsAccepted input
viscosityViscosityRequired. Finite number; minimum 0.
lengthLengthRequired. Finite number; minimum 0.
widthInterval, bin, geometry or dimension width under the specific convention above.Required. Finite number; strictly above 0.
heightHeightRequired. Finite number; strictly above 0.
Output fieldInterpretationReturned shape
resistancePressure drop per volumetric flow; Pa s/m³ with compatible SI inputs.Required. Finite number.
json
{
  "input": {
    "viscosity": 1,
    "length": 2,
    "width": 4,
    "height": 1
  },
  "output": {
    "resistance": 7.121661721068249
  }
}

Limitations and assumptions

  • This is a rectangular-channel laminar-flow approximation with compatible units; inlet effects, non-Newtonian behavior and a complete fluidic network are omitted.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified properties, calibration and the complete applicable engineering model; assess actual laboratory/device conditions and biological suitability separately.

References

  1. Calculation and input contract: bioengineering/microfluidic-hydraulic-resistance-one-channel — tool.io